Ac Voltage; Ac Current; Dc Current - Facom 712B Notice D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

4.4 AC Voltage

1. Insert the red test lead in the "INPUT" jack and the
black lead in the "COM" jack.
2. Move the rotary switch to the"
the test leads across the circuit or load to be measured.
3. Read measured voltage on the display.
Use extra caution when measuring high voltages to
avoid electric shock or damage.
Do not attempt to measure voltages above 600V AC to
prevent injury or damage to the meter.

4.5 AC Current

1. Move the rotary switch to the "
proper range.
2. Press the trigger and insert one conductor inside the
jaws. Only clamp one conductor, multiple conductors
with different current directions will cancel out readings.
3. Read measured current and the frequency value on the
LCD display.

4.6 DC Current

1. Move the rotary switch to the "
proper range
2. Press the trigger, open the clamp and insert one
conductor inside the jaws only clamp one conductor
multiple conductors with different current directions will
cancel out readings.
3. Read measured current on the LCD display.
NU-712B_0618 7 langues.indd 27
V
"position. Connect
CAUTION
WARNING
A
"position with the
A
"position with the
27
22/06/2018 11:50:59

Publicité

Table des Matières
loading

Table des Matières