Electrical connection – Commissioning with factory settings
4
Ä
Connect 5 V DC voltage supply and, if necessary, switching input and RS 232
interface.
Ä
If necessary, connect BPS 8 with the KDS S-M12-5A-M12-5x-P1-xxx inter-
connection cable (accessory) to the MA 8.1 modular connection unit (RS 232
interface, accessory) or to the MA 8-xx modular connection unit (RS 485 in-
terface, accessory).
Ä
Switch on supply voltage ‑ the status LED must illuminate green.
Ä
Activate measurement via switching input or interface. The laser switches it-
self on.
Ä
At a distance of approx. 100 mm, move the BPS 8 past the bar code tape.
The device outputs the position data.
LED indicators
3
LED
Status
B1
OFF
Status LED
Green, flashing
Green, continuous light Operational readiness
Red, flashing 200 ms
Red, continuous light
Orange, flashing
200 ms
B2
OFF
Decode LED
Green, continuous light Position values valid
Red, continuous light
Orange, flashing
Working range/reading distance
5
H
Reading distance from the BPS 8 to the bar code [mm]
J
Reading field width [mm]
Description
No supply voltage
Initialization phase of the device
Warning
Error; no function possible
Service operation active
Positioning deactivated
Position values invalid
Marker label detected