Maintenance - Piusi P 3.5 Installation, Utilisation Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
ATTENTION
Using the pump unit in a dry state, i.e. with no fluid or with insufficient fluid, can damage it
irreparably. Dry pumping increases the operating speed of the pneumatic motor, resulting
in overheating and possible failure.
If operating at low temperatures, we recommend that you use systems to protect against
the formation of ice.
Don't shut off the air supply while the pump is working. For its correct working never go
down below the declared pressure.
14.

MAINTENANCE

Safety instructions
The system is designed and manufactured to require minimal
maintenance. Before carrying out any maintenance operation, it is
imperative to decompress the dispensing system with the aid of the
bleed ball valves. It is strictly forbidden to carry out any maintenance
operation if the circuit contains compressed air capable of causing the
pump to start suddenly.
Personal protective equipment (PPE) must be worn when carrying out
maintenance work.
Take account of the following minimum recommendations for correct
operation of the pump.
Authorised
All maintenance must be performed by qualified personnel. Tampering
maintenance
can lead to performance degradation, danger to persons and/or
personnel
property and may result in the warranty being voided.
Measures to be
Make sure that the label affixed to the dispensing system does not
taken
deteriorate over time or come off.
EVERY DAY:
¦ check that the hoses are in sound condition.
ONCE A YEAR:
¦ check the components of the air circuit.
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
PIUSI P 3.5 - PIUSI P 5.5
17
/112

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P 5.5

Table des Matières