3.
Push the power connector firmly into the connector
sleeve.
4.
Use a heat gun to shrink the heatshrink over the
connector.
6.2
Cutting Rope Lights
1.
Make sure the mains power is switched off.
2.
The rope light can be cut at specific intervals. These are indicated with following
symbol:
Cut the wires only at the marks
3.
Use a sharp cutter and make a clean straight cut.
6.3
Assembling the Connectors
See section Technical Specifications below for product codes.
The maximum length of the rope light assembly is 45 m. Exceeding the maximum
length may cause overheating and fire.
1.
Make sure the mains power is switched off.
2.
Use connectors (in-line, L, T, or X-shaped) to connect the rope light sections.
3.
Always check that the pins are correctly inserted into the fitting.
4.
Apply some glue and push the 2 parts together making sure that it fits well. Apply
glue only on the plastic parts – not on the conductive parts.
5.
Let the glue dry for about 15 minutes before using the unit.
6.4
Attaching End Caps
See section Technical Specifications below for product codes.
Attach the end caps as follows:
1.
Apply the special glue to the rope light.
Apply glue only on the plastic parts – not on the conductive parts.
2.
Gently push the end cap on the rope light end.
3.
Important: Let the glue dry for about 15 minutes before using the unit.
V. 02 – 22/10/2018
HQRLxxxxx
.
.
6
©Velleman nv