6. MAINTENANCE AND TROUBLE-SHOOTING
Should problems arise with the light fitting's operation, turn off the power for a few moments, then recheck
the operation. Check also that the lamps are fixed securely in their lamp holders. If this has no effect, change
the lamps. Check also the securing of the wires to the terminal block.
Always switch off the power before changing lamps! If the lamp has been changed while the power is
on, switch off the power for at least 30 seconds after changing the lamp.
If the PIR sencor fails to work though the power supply is on, switch off the power supply before removing
the PIR sensor from the light fitting and sending it for replacement.
7. CLEANING
The lens should be cleaned when necessary using a damp cloth. Do not use cleaning agents or solvents
as these may damage the lens surface!

8. TECHNICAL SPECIFICATIONS

Minimum mounting height 1.7 m.
Features a Passive Infra Red sensor unit (PIR).
Power supply 220 - 240 V, 50 / 60 Hz.
Detection area: horizontal 360°, vertical approx. 135°
Switch off 1 - 30 min after movement ceases (TIME setting).
Sensitivity (within detection range) SENS, illumination level LUX (1 lx - infinity) and TIME setting.
...6D, .../...4E and.../...7E: LUX - position max (= infinity).
...4E: electronic ballast , starting time 1 - 2 sec.
...6D: dimmable electronic ballast: illumination level approx. 1 - 10% when continuously on. This rises
to 100% when the PIR reacts to movement.
Max. external load: 400VA light fitting load.
Operating modes: automatic operation in dusk, test mode and lux setting mode.
LUX The PIR sensor always reacts if the illumination is lower than the operat-
ing threshold set on the potentiometer (LUX setting). If the LUX potentiometer
is turned so that a dim LED (red or green) becomes brighter, the sensor goes
into the illumination level setting mode. In the setting mode the sensor switch
the light fitting off and it will not come on for approx. 5 seconds. The ambient
illumination level is indicated by the LEDs at the point where the green and red
LEDs changeover. If the LUX level set is higher than the ambient illumination,
the red LED will glow brightly and if it is lower the green LED will glow brightly.
N.B. The LUX setting is affected by the angle of the incident light, as also by
e.g. reflection from the setter's clothing. The LUX level can be set between
1 lx - infinity.
NB! In the luminaire models ...6D and .../... (=continually burning lamp) hold
the LUX - potentiometer to MAX - position (infinity).
TIME
The TIME potentiometer enables the length of time the light remains
on after the sensor's last reaction to movement to be adjusted. Time setting 1
minute starts when the potentiometer is in MIN -position. The setting range is
1 min - 30 min.