Technical Data - Victron energy Phoenix 12/180 Manuel

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3. Technical data

Phoenix Inverter
Cont. AC power at 25 ° C (VA)
Cont. power at 25 ° C / 40 ° C (W)
Peak power (W)
Output AC voltage / frequency
Input voltage range (V DC)
Low battery alarm (V DC)
Low battery shut down (V DC)
Low battery auto recovery (V DC)
Max. efficiency 12 / 24 / 48 V (%)
Zero-load power 12 / 24 / 48 V (W)
Zero-load power in Power Saving mode
Protection
(2)
Operating temperature range
Humidity (non condensing)
ENCLOSURE
Material & Colour
Battery-connection
Standard AC outlets
Other outlets (at request)
Protection category
Weight (kg / lbs)
Dimensions (hxwxd in mm)
(hxwxd in inches)
ACCESSORIES
Remote control panel
Remote on-off switch
Automatic transfer switch
STANDARDS
Safety
Emission / Immunity
3. Description of the Digital Multi Control panel
1. Battery cables of 1.5 meter (12/180 with cigarette plug)
2. Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
3. Non linear load, crest factor 3:1
12 Volt
24 Volt
48 Volt
(3)
87 / 88 / 89
2,6 / 3,8 / 4,0
IEC-320 (IEC-320 plug included), Schuko,
72x132x200
2.8x5.2x7.9
12/180
24/180
48/180
180
175 / 150
350
110VAC +/- 5% or 230VAC +/- 3%
50Hz or 60Hz +/- 0,1%
10,5 - 15,0 / 21,0 - 30,0 / 42,0 - 60,0
11,0 / 22 / 44
10,5 / 21 / 42
12,5 / 25 / 50
n. a.
a - e
-20 to +50° C (fan assisted cooling)
max 95%
aluminium (blue Ral 5012)
1)
or Nema 5-15R
United Kingdom, Australia/New Zealand
IP 20
2,7 / 5,4
n. a.
Two pole connector
Filax
EN 60335-1
EN55014-1 / EN 55014-2
12/350
24/350
48/350
350
300 / 250
700
89 / 89/ 90
3,1 / 5,0 / 6,0
n. a.
1)
3,5 / 7,7
72x155x237
2.8x6.1x9.3
n. a.
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Phoenix 24/180Phoenix 48/180Phoenix 12/350Phoenix 24/350Phoenix 48/35012/180 ... Afficher tout

Table des Matières