Process of rebuilding the device for another gas type
The device is set and checked for liquefied gas (see the label). Rebuilding for another gas type must be done by
qualified person. Nozzles are included in the packet with instructions for use.
Exchange of the main burner´s nozzle: picture D
Remove upper parts of the burner (A), screw up the nozzle (D) and screw in the new one for required gas type
- see technical chart.You need not to regulate air feeder.

Important:

After having rebuilt the gas type, change the data on the label.
How to check the operation of the device:
• check the gas leaks
• check the ignition and flame of the main burner
• check the ignition and flame of the main burner for min. performance (sporo)
• check whether the flame of the burner licks the thermoelement and whether it is blue
• we recommend to the user when using the device to proceed according to the instructions for use
Regulation of the flame by the lower performance (sporo):
Adjust the low performance (sporo) and then regulate the flame with screw which is situated in the body of the
tap next to the tap shaft.
Process of regulation:
• remove the regulation tap knob (pull to yourself)
• there is slot for regulation next to the tap shaft
• regulate the flame with the small flat screwer

InstructIon for usE

Ignition and regulation of the burner without perpetual flame : pictures A,B –standard implementation
Turn the regulation knob of the competent burner (1) into position „ignition of the main burner" and then press it
down and hold it. Ignite the burner with lighter or matches. After ignition of the burner hold the knob (1) pressed
several seconds till the thermofuse gets hot. Then release the button. If the flame goes out repeat the whole
process once more.
- lower performance sporo: picture A.B
By turning the knob (1) into position „sporo" you set the burning of the burner for sporo (lower performance)
- how to switch the competent burner off: picture A,B
Turn the knob (1) into position"0".
Ignition and regulation of the burner with perpetual flame : pictures A,B – implementation in extra pay
Turn the regulation knob of the competent burner (1) into position „ignition of the helping burner" and then press
it down and hold it. Ignite the helping burner with lighter or matches.The helping burner is in openning in cover
of the burner. After ignition of the helping burner hold the knob (1) pressed several seconds till the thermofuse
gets hot. Then release the button. If the flame goes out repeat the whole process once more.Turning the knob
(1) in position full performance –the main burner will ignite.