When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero.
Automatic reset to zero when
main counter = preset value 2.
Preset 1 relative to Preset 2
7.8.3.3 Submenu for configuration
Submenu for matching the input
pulses to the display.
Multiplication factor
can be programmed from
00.0001 to 99.9999 The setting
00.0000 will not be accepted.
Division factor
can be programmed from
01.0000 to 99.9999
A setting < 01.0000 will not be
accepted.
Decimal point setting
(only optical function)
0
0.0
0.00
0.000
0.0000
0.00000
Set value
Set value can be programmed
from -999999 to 999999
A previously programmed
decimal point will be displayed
7.8.3.4 Submenu for reset mode
Submenu for setting the reset
mode
Reset mode
Manual reset (reset key) and
electrical reset (reset input)
No reset possible
(reset key and reset input
inhibited)
Only electrical reset possible
(reset input)
Only manual reset possible
(reset key)
Page 10 | ENG
no decimal place
1 decimal place
2 decimal places
3 decimal places
4 decimal places
5 decimal places
Electrical Reset:
Always resets only the main counter.
Manual Reset:
Resets the main counter (ACTUAL) and
auxiliary counters (BATCH or TOTAL), if the
value of the main counter or the value of an
auxiliary counters is shown on the display.
7.8.3.5 Preset 1
see below 7.9.5.5
7.8.3.6 Preset 2
see below 7.9.5.6

7.8.4 Tacho/Frequency meter

7.8.4.1 Submenu for the Signal and
Control inputs
Submenu for programming the
signal and control inputs
Input polarity
PNP: switching to Plus
for all inputs in common
NPN: switching to 0 V
for all inputs in common
Filter for signal inputs INP A
and INP B
maximum count frequency
Damped to approx. 30 Hz
(for control with mechanical
contacts)
Input mode Frequency
measurement
(see also under 17.)
Simple frequency
measurement
INP A: Frequency input
INP B: no function
Differential measurement
[A – B]
INP A: Frequency input A
INP B: Frequency input B
Total measurement [A + B]
INP A: Frequency input A
INP B: Frequency input B
Frequency measurement with
direction detection [Quad]
INP A: Frequency input 0°
INP B: Frequency input 90°
Ratio measurement [A / B]