OPERATION AND USE
Sensor Fault
Outlet
Temp.
Sensor Fault
Ambient Temp.
Sensor Fault
Coil
Temp.
Sensor Fault
Suction
Temp.
Sensor Fault
Discharge Temp.
Sensor
P081
Fault
High
Pressure
Prot.
Low
Pressure
Prot.
Flow
Switch
Prot.
Anti-freezing
Prot.
Primary
Anti-freezing
Prot.
Secondary
Anti-freezing
Prot.
Inlet and outlet
temp. too big
Low temperature
Non
protection
Comp.
E051
Overcurrent Prot.
Exhaust Air over
P082
Temp Prot.
Communication
Fault
Antifreeze
Temp.
Sensor
Fault
Waterway
Anti-freezing
short circuit
The temp. Sensor is broken or
P02
short circuit
The temp. Sensor is broken or
P04
short circuit
The temp. Sensor is broken or
P05
short circuit
The temp. Sensor is broken or
P07
short circuit
The temp. Sensor is broken or
short circuit
E01
The high-pressure switch is broken
E02
Low pressure1 protection
No water/little water in water
E03
system
E07
Water flow is not enough
E19
The ambient temp. Is low
E29
The ambient temp. Is low
Water flow is not enough
E06
and low differential pressure
The environment temp. is low
The compressor is overload
The compressor is overload
Communication failure between
E08
wire controller and mainboard
antifreeze temp sensor is broken or
P09
short circuited
water temp. or ambient temp. is
E05
too low
Check or change the temp. Sensor
Check or change the temp. Sensor
Check or change the temp. Sensor
Check or change the temp. Sensor
Check or change the temp. Sensor
Check the pressure switch and cold
circuit
Check the pressure switch and cold
circuit
Check the pipe water flow and
water pump
Check the pipe water flow and
whether water system is jammed
or not
Check the pipe water flow and
whether water system is jammed
or not
Check whether the system of the
compressor running normally
Check whether the system of the
compressor running normally
Check
the
wire
connection
between remote wire controller
and main board
check and replace this temp sensor