Télécharger Imprimer la page
Leviton Sureslide Directives D'installation
Leviton Sureslide Directives D'installation

Leviton Sureslide Directives D'installation

Commande à glissière de vitesse de ventilateur

Publicité

Liens rapides

C O L L E C T I O N B Y L E V I T O N
Single Pole (1 location)
120VAC, 60Hz
Slide Fan Speed Control
Cat. No. 6627, 5A
INSTALLATION INSTRUCTIONS
Unipolaire (1 emplacement)
120 V c. a., 60 Hz
Commande à glissière
de vitesse de ventilateur
Nº de cat. 6627, 5 A
DIRECTIVES D'INSTALLATION
Unipolar (1 ubicación)
120VCA, 60Hz
Control Deslizante
p/Velocidad de Ventilador
No. de Cat. 6627, 5A
INSTRUCCIONES DE INSTALACION
R
DI-100-06627-20A
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit
of anyone else that this product at the time of its sale by Leviton is free of
defects in materials and workmanship under normal and proper use for
two years from the purchase date. Leviton's only obligation is to correct
such defects by repair or replacement, at its option, if within such two
year period the product is returned prepaid, with proof of purchase date,
and a description of the problem to Leviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little
Neck, New York 11362-2591 (In Canada send to Leviton Mfg. of Canada
Ltd., 165 Hymus Blvd., Point Claire, (Quebec), Canada H9R 1E9). This
warranty excludes and there is disclaimed liability for labor for removal
of this product or reinstallation. This warranty is void if this product is
installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal
operating conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied
warranty is required by the applicable jurisdiction, the duration of any
such implied warranty, including merchantability and fitness for a
particular purpose, is limited to two years. Leviton is not liable for
incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or
profits or delay or failure to perform this warranty obligation. The remedies
provided herein are the exclusive remedies under this warranty, whether
based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
R
DI-100-06627-20A
• Leviton's Decora
®
style design
• Operates any number of ceiling fans up to rating limits
• Fits standard wall boxes
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING:
TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, FLUORESCENT LIGHTING, A MOTOR- OR A
TRANSFORMER-OPERATED APPLIANCE OTHER THAN APPROPRIATE CEILING FANS.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, THIS CONTROL IS TO BE USED WITH A CEILING FAN THAT IS MARKED AS SUITABLE FOR USE WITH A SOLID-STATE FAN SPEED
CONTROL AND IS RATED 120 VOLTS, 5 AMPERES MAXIMUM.
WARNING:
FOR USE ON CEILING PADDLE FANS WITH SPLIT-CAPACITOR OR SHADED POLE MOTORS ONLY. PLEASE REFER TO FAN MANUFACTURER'S INSTRUCTIONS OR RATING LABELS ON THE
MOTOR TO CONFIRM TYPE. USE WITH ANY OTHER TYPES OF MOTORS OR EQUIPMENT MAY CAUSE OVERHEATING AND/OR DAMAGE TO THE MOTORS OR EQUIPMENT.
OTHER CAUTIONS:
1. DISCONNECT POWER WHEN SERVICING FIXTURE.
2. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR CU/AL.
MULTI-FAN CONTROL:
Any number of fans of the same type may be controlled by a single fan speed control provided that the total amperage of the fans does not exceed the amperage rating of the fan speed control.
GANGING/DERATING:
When combinations of dimming and/or speed controls are installed in a ganged wall or outlet box, derating is required. When two devices are mounted in a ganged box, the maximum load per device shall not exceed 4A
or 500 watts. When three or more devices are mounted in a ganged box, the maximum load shall not exceed 3A or 400 watts.
TO INSTALL:
WARNING:
1.
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
2. Remove existing wallplate and switch, if applicable.
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure the ends of wires are straight.
4. Connect wires per WIRING DIAGRAM as follows: Twist strands of each lead tightly together and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure no
bare conductors show below the wire connectors. Secure each connector with electrical tape.
5. Restore power at circuit breaker or fuse. Holding speed control securely by its insulated case, make sure fan is rotating by moving ON/OFF rocker switch to ON position and sliding control lever to a middle position.
6. Interrupt power by moving ON/OFF rocker switch to OFF position. Slide control bar DOWN to lowest position (closest to ON/OFF rocker switch).
7. After fan stops rotating, restore power by moving ON/OFF rocker switch to ON position (keep control bar down at lowest position). Fan should rotate at low end speed after power has been restored. If fan blades are
not rotating, adjust low end (slowest) fan speed as follows:
A. Insert a small screwdriver into trim slot.
B. Turn clockwise to increase fan speed, counterclockwise to lower fan speed. The low end trim is now set.
8. TURN OFF POWER. Installation may now be completed by carefully positioning all wires to provide room in outlet box for fan speed control. Mount fan speed control into box with mounting screws supplied. Attach
wallplate.
9. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE.
Slide bar control up or down for desired fan rotation speed. ON/OFF rocker switch will turn fan ON at speed set by slide bar.
• Style de la gamme Decora
®
de Leviton
• Compatibilité à de nombreux modèles de ventilateurs dans les limites prescrites
• S'adapte à toute boîte simple standard
AVERTISSEMENT :
INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L'ÉLECTRICITÉ EN VIGUEUR.
AVERTISSEMENT :
À DÉFAUT DE BIEN COMPRENDRE LES DIRECTIVES SUIVANTES, FAIRE APPEL À UN ÉLECTRICIEN QUALIFIÉ.
AVERTISSEMENT :
POUR ÉVITER LA SURCHAUFFE OU L'ENDOMMAGEMENT ÉVENTUEL DE CE DISPOSITIF ET D'AUTRES APPAREILS RACCORDÉS, NE PAS L'INSTALLER POUR COMMANDER UNE
PRISE, UN LUMINAIRE FLUORESCENT, OU UN APPAREIL MOTORISÉ OU À TRANSFORMATEUR AUTRE QU'UN VENTILATEUR POUR PLAFOND APPROPRIÉ
AVERTISSEMENT :
POUR RÉDUIRE LES RISQUES D'INCENDIE OU DE CHOC ÉLECTRIQUE, N'UTILISER CE DISPOSITIF NE DOIT ÊTRE UTILISÉ QUE POUR LES VENTILATEURS DE PLAFOND IDENTIFIÉS
COMME ÉTANT CONÇUS POUR PERMETTRE UNE RÉGULATION DE LES VITESSE ET DOIVENT AUSSI AVOIR DES VALEURS NOMINALES MAXIMALES DE 120 VOLTS C.A., 5 AMPÈRES.
AVERTISSEMENT :
NE PEUT ÊTRE UTILISÉ QU'AVEC DES MOTEURS À CONDENSATEUR OU À BAGUE DE DÉPHASAGE; VEUILLEZ CONSULTER LES DIRECTIVES DU FABRICANT DE VENTILATEURS, OU
L'ÉTIQUETTE SIGNALÉTIQUE APPOSÉE SUE LE MOTEUR, POUR EN CONFIRMER LE TYPE; UNE UTILISATION AVEC TOUT AUTRE TYPE DE MOTEUR OU D'APPAREIL POURRAIT CAUSER LA SURCHAUFFE,
VOIRE MÊME LE BRIS, DE CE MOTEUR OU DE CET APPAREIL.
AUTRES MISES EN GARDE :
1. LORS D'UNE VÉRIFICATION D'APPAREILS, COUPER L'ALIMENTATION.
2. UTILISER CE DISPOSITIF SEULEMENT AVEC DU FIL DE CUIVRÉ; POUR LE FIL EN ALUMINIUM, UTILISER SEULEMENT LES DISPOSITIFS MARQUÉS CO/ALR OU CU/AL.
COMMANDE DE PLUSIEURS VENTILATEURS : un seul dispositif peut commander plusieurs ventilateurs, à condition que la puissance totale de ces derniers ne dépasse pas les valeurs nominales de la commande.
GROUPEMENT/ABAISSEMENT : lorsque des commandes de gradation de lumière ou de vitesse sont combinées, on doit opérer un certain déclassement; quand deux unités sont combinées, la charge maximale par
unité ne devra pas excéder 4 A ou 500 W.; quand plus de deux unités sont combinées, cette charge ne devra jamais dépasser 3 A ou 400 W.
INSTALLATION :
AVERTISSEMENT :
1.
POUR ÉVITER LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURE MORTELLE, COUPER LE COURANT AU FUSIBLE OU AU DISJONCTEUR ET S'ASSURER QUE
LE CIRCUIT SOIT BIEN COUPÉ AVANT DE PROCÉDER À L'INSTALLATION.
2. Retirer la plaque murale et l'interrupteur existant, le cas échéant.
English
FEATURES
Slide control for easy and precise operation
Minimum Speed Adjustment
INSTALLATION INSTRUCTIONS
OPERATION
Français
CARACTÉRISTIQUES
• Commande à glissière pour un réglage simple et précis
• Réglage de la vitesse minimale
DIRECTIVES D'INSTALLATION

Publicité

loading

Sommaire des Matières pour Leviton Sureslide

  • Page 1 Leviton warrants to the original consumer purchaser and not for the benefit 9. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE. of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for OPERATION two years from the purchase date.
  • Page 2 5. Rétablir le courant au fusible ou au disjoncteur; en ayant bien soin de tenir le boîtier du commande de façon sécuritaire, assurez-vous du bon fonctionnement du ventilateur en plaçant l’interrupteur MARCHE/ARRÊT à de sa vente par Leviton, et n’en présentera pas tant qu’il est utilisé de façon normale et adéquate, pendant une période de 2 ans suivant la date d’achat.