BTL5-T1_ _-M_ _ _ _-P-S103
Micropulse Linear Transducer – Profile Housing
3

Installation

3.1

Transducer installation

Ensure that no strong electrical or
magnetic fields are present in the
immediate vicinity of the trans-
ducer.
Any orientation is permitted. The
supplied mounting brackets and
cylinder head screws allow the
transducer to be mounted on a flat
machine surface.
Fig. 3-1: Dimensional drawing (BTL5...P-S103 transducer with floating magnet BTL5-P-3800-2)
Fig. 3-2: Dimensional drawing (BTL5...P-S103 transducer with captive magnet BTL5-F-2814-1S)
4
english
A sufficient quantity of mounting
brackets is supplied.
Recommended installation:
Distance A = approx. 80 mm
Distance B = approx. 250 mm (be-
tween the individual clamps)
To prevent resonant frequencies
under vibration loads of >50 g, we
recommend placing the mounting
clamps at irregular intervals.
Nominal stroke
Magnet
NL
Nominal stroke
NL
The supplied isolation bushings are
used to electrically insulate the
transducer from the machine
(➥ ➥ ➥ ➥ ➥ Fig. 3-6 and chapter 6.6 Noise
elimination).
The Micropulse transducer in pro-
file housing is suitable both for
floating, i.e. non-contacting mag-
nets (➥ ➥ ➥ ➥ ➥ Fig. 3-1, also page 5) and
for captive magnets (➥ ➥ ➥ ➥ ➥ Fig. 3-2,
also page 6).
Black,
round
marking