Cleaning
FREQUENCY
On each charge
Every week
Every 2 weeks
Every 2 weeks
Every month
Every 2 weeks (RC119N only)
* Time slots are to be intended as actual working time.
Ordinary maintenance
FREQUENCY
Every 2 weeks
Every week
Every 2 weeks
Every 2 weeks
Every month
Every 2 weeks (RC119N only)
* Time slots are to be intended as actual working time.
9- EXTRAORDINARY MAINTENANCE
• Material holder tube gaskets replacement: after extensive use air leakages on the back of the material holder tube may occur.
The outlet OR needs to be replaced. Contact your dealer.
• Replacement of the piston lip gasket (also for RC119N thrust piston): after extensive use an excessive waste of the thrust
piston lip seal may occur, thus leading to a lower performance and air leakage on the front of the gun. The lip seal needs to be
replaced. Contact your dealer.
10- FAULTS AND BREAKDOWNS
In the event of faults and/or breakdowns of gun components, do not try to repair them. Do not use the gun with temporary
repairs or damaged or worn out components, or with non-original components used as a replacement. Repairs shall be carried
out by authorized workshops or directly by the manufacturer. Contact your dealer.
11- FREQUENT ISSUES
INCONVENIENTS
After charging the material and connecting
the gun to the system, nothing occurs when
pushing the lever.
Irregular or slow extrusion
Loss of pressure and extrusion power of
the gun.
The gun does not work properly.
12 - WARRANTY
The guns and their tools are covered by the warranty, if not subject to wear and tear, in compliance with European regulations.
All components deemed faulty will be replaced by our technical department with no charges, only if returned without tampering
or stains and if delivered DDP to our plant. The manufacturing company is not liable for personal injuries or damage to property
due products or gun misuses, which are expressly forbidden by this manual. In addition the company recommends to carefully
comply with the user's instructions. The sale of disassembled, altered or incomplete guns or tools (upon specific request of the
client) is not covered by warranty as our technical department could not test and approve them.
CAUSES
Fresh material residues
Dusts or filth
Dusts, filth or material residues
Dusts or filth
Dusts or filth
Dusts, filth or material residues
OPERATION
Threads greasing
Material holder tube inner greasing
Dusts, filth or material residues
Dusts or filth
Dusts or filth
Transmission bar greasing
to be carried out by the maintenance operator / dealer
to be carried out by the maintenance operator / dealer
CAUSES
No feeding.
Very thick product.
Slow front ring nut. Damaged
cartridge lip
Damaged or dirty components.
11
DESCRIPTION
Always carefully remove material residues from the gun surfaces,
dispose in compliance with the applicable regulations in the country
of use.
Carefully clean the exhaust air outlets (11.1) with a clean cloth and a
detergent and check for potential clogging.
Carefully clean the front ring nut thread (2) with a clean cloth and a
detergent and the relevant thread on the cartridge holder tube.
Carefully clean the connector between the gun and the feeding
system (6) with a clean cloth and a detergent.
Carefully clean the gun with a clean cloth and a detergent, especially
the handle, as ease of holding is a priority.
After removing the material holder tube, carefully clean the
transmission bar with a clean cloth and a detergent.
DESCRIPTION
Grease the ring nut thread (2) as well as the relevant cartridge holder
tube thread, with lubricating grease.
Grease the material holder tube inner surface with a brush.
Carefully clean the front ring nut thread (2) and the relevant
cartridge holder tube thread with a clean cloth and a detergent.
Carefully clean the connector between the gun and the feeding
system with a clean cloth and a detergent.
Carefully clean the gun, with a clean cloth and a detergent, especially
the handle, as ease of holding is a priority.
After removing the material holder tube carefully clean the
transmission bar. Manually move forward the piston twice.
REMEDIAL ACTIONS
Check disconnector opening on the system. Check pressure
regulators. Check for potential leakages in the tube.
Increase air capacity with the flow regulator. Increase air pressure
with the pressure regulator.
Tighten the ring nut properly. Check cartridge user's instructions.
Replace the damaged cartridge.
Carry out cleaning and ordinary maintenance operations. If the issue
is due to damaged components, contact your dealer.
Manual - English