GAS FRYTOP
The appliance described in this manual has been built in compliance
with the UNI EN 203 and UNI EN 437 standards.
The appliance must be installed by qualified personnel according to the
regulations and directives in force in the country where it is installed, as
well as to the instructions in this manual.
This appliance has been designed exclusively for cooking food.
To dispose of the packaging, follow directives in force.
Switch the appliance off in the case of failure or malfunction.
Care must be taken when using the appliance because the cooking surfaces are very hot.
In the models FTL.. and FTR.. the plate can reach the maximum temperature of ~330°C.
In the model FTC.. the plate can reach the maximum temperature of ~300°C.
This instruction manual refers to the installation and use of the Category
II2H3+ gas frytop.
The self-adhesive polyester data plate "T" (pic.2) is behind the control
panel (inside the appliance).
It contains the following information:
Model
Serial number:
Category:
Year of construction:
Nominal thermal capacity:
Type of construction:
Test base:
Connection pressure:
Consumption:
Before you install the appliance, make sure that the gas
company has authorised the installation, then compare
the relevant data (data plate) with the local gas supply.
Remove the packaging from the appliance as well as the protective
plastic wrap and, if necessary, remove any traces of glue with a suitable
solvent. To dispose of the packaging, follow directives in force (for more
details refer to the chapter "ECOLOGY AND THE ENVIRONMENT").
Before connecting the appliance to the gas network, check the data
plate to make sure that the unit has been set and tested for the type of
gas available. If the gas type indicated on the data plate is not the same
as the one available, refer to the paragraph "CONVERSION AND
ADAPTATION".
Connect the appliance to the gas distribution network using only metal
pipes with a suitable diameter, and install a homologated shut-off cock
between the appliance and the gas distribution network. If flexible pipes
are used, they must be made of stainless steel according to the
directives in force. When installing the appliance, you must observe and
respect all the regulations in force, such as:
Characteristics of the appliance
FT_4_G7
xxxxxx
II2H3+
xxxx
7 kW
A1
UNI EN 203
G30
28-30/37 mbar
G20
20 mbar
G30
XX Kg/h
G20
XX m
/h
3
Connection to the gas mains
General Instructions
To use the appliance correctly follow the warnings below:
The appliance must never be left unattended when it is being used.
The appliance is intended for professional use and therefore only
qualified personnel should use it.
The appliance should be installed under a extractor hood for
evacuating any cooking fumes.
The supplementary data plate is made of self-adhesive polyester and is
affixed near the data plate; it contains all the information regarding the
setting of the appliance. The FTL/R/C4_G7 has one burner and a fitting
for gas connection. The FTL/R/C8_G7 has two burners and a fitting for
gas connection. The connection to the "G" gas distribution network
(pic.1) meets ISO 7/1 and ISO 228/1 (DK) standards with a ø½"
connection, and it is situated at the back of the appliance.
The structure of the appliance is made of stainless steel, the burners are
made of steel and the freestanding models have height-adjustable feet.
The main gas pipe is made of galvanised steel. The pipes that connect
the cock to the burner are made of copper.
Install a shut-off cock between the appliance and the gas
mains.
■ UNI-CIG 8723 safety standard, Act n.46 of 5th March 1990 and
circular n.68.
■ Regional and/or local regulations, such as building codes;
■ Accident prevention regulations in force;
■ Fire prevention regulations;
■ Applicable I.E.C. regulations.
The appliance has an equipotential terminal "N" (pic.1) located at the
back.
The appliance can be installed alone or in line.
Respect a minimum distance of 80mm between the appliance and any
walls made of flammable material, partitions, kitchen furniture or nearby
equipment.
All the surfaces in contact with the appliance must be covered with
non-combustible heat insulating material.
After installing the appliance check the leak holding capacity of the
fittings in order to eliminate any leaks. We suggest you use non-
corrosive foam products, such as leak detection sprays.
GB / IE - 1