Symptom
There is no debris blocking
the impeller and the pressure
is still low.
The pump is leaking water
between the motor and pump
body.
The pump gets hot and shuts
off periodically.
Section 7. Parts, Product Specifications and Technical Data
7.1

Replacement Parts List

To order or purchase parts for Zodiac
you need, contact Zodiac technical support at 800.822.7933 or send an e-mail message to:
productsupport@fluidra.com
Key No.
Description
1
Single-speed Motor & Hardware, SHPF
1
Single-speed Motor & Hardware, SHPF
1
Single-speed Motor & Hardware, SHPF
1
Single-speed Motor & Hardware, SHPF
1
Single-speed Motor & Hardware, SHPF
1
Single-speed Motor & Hardware, SHPF
1
Single-speed Motor & Hardware, SHPF
1
Single-speed Motor & Hardware, SHPM
1
Single-speed Motor & Hardware, SHPM
1
Single-speed Motor & Hardware, SHPM
1
Single-speed Motor & Hardware, SHPM
1
Single-speed Motor & Hardware, SHPM
1
Two-speed Motor & Hardware, SHPM
1
Two-speed Motor & Hardware, SHPM
1
Two-speed Motor & Hardware, SHPM
1
Single-speed Motor & Hardware, SHPF, 3 Phase
1
Single-speed Motor & Hardware, SHPF, 3 Phase
1
Single-speed Motor & Hardware, SHPF, 3 Phase
1
Single-speed Motor & Hardware, SHPF, 3 Phase
1
Two-speed Motor & Hardware, SHPF
1
Two-speed Motor & Hardware, SHPF
1
Two-speed Motor & Hardware, SHPF
2
Backplate Kit w/Hardware, O-ring & Mech Seals,
SHPF/SHPM
2
Backplate Kit w/Hardware, O-ring & Mech Seals, SHPF
3
Impeller Replacement Kit, SHPF
3
Impeller Replacement Kit, SHPF
3
Impeller Replacement Kit, SHPF
Jandy
Stealth
Pumps
®
The pump impeller and diffuser are showing signs of normal wear. Have a qualified
service technician check the impeller and diffuser and replace as necessary.
If the pump is part of a relatively new installation, it could be an electrical problem.
Contact a qualified service technician. Have the technician check for loose electrical
connections and check the voltage at the pump motor while it is in operation. The
voltage must be within 10% of the motor's data plate rating. If the voltage is not
within 10%, contact a qualified electrician and/or the local power service provider.
This is caused by a damaged or failed mechanical seal. Pump seal is leaking air.
Have a qualified service technician replace the seal.
Ensure that there is adequate room around the motor to circulate air and keep the
motor cool. Have a qualified electrician check for loose connections and check the
voltage at the pump motor while it is in operation. The voltage must be within 10%
of the motor's data plate rating. If the voltage is not within 10%, contact a qualified
electrician and/or the local power service provider.
pumps, contact your nearest Zodiac dealer. If they cannot supply you with what
®
|
Operation Manual
Possible Problem/Solution
Model No. (HP)
.50
.75
1.0
1.5
2.0
3.0
5.0
.75
1.0
1.5
2.0
2.5
1.5
2.0
2.5
1.0
1.5
2.0
3.0
1.0
1.5
2.0
.50-3.0
5.0
.50
.75
1.0, 1.0-2
Page 15
ENGLISH
Order Part No.
R0445114
R0445101
R0445102
R0445103
R0445104
R0445105
R0490200
R0479301
R0479302
R0479303
R0479304
R0479305
R0479307
R0479308
R0479309
R0479101
R0479102
R0479103
R0479104
R0445113
R0445106
R0445107
R0445200
R0445201
R0807204
R0807203
R0807202

Publicité

Table des Matières
loading

Table des Matières