Assembly and installation (A, B)
Press the two floating bodies (1) into the channels in the container (2) provided for this purpose until they audibly
engage. Align the air distributor (4) as shown in figure B.
Place the unit in the pond. Submerge the unit until the pump chamber (3) and the container (2) are completely flooded.
Ensure that the skimmer flap (5) is in its correct position.
If necessary, anchor the unit to limit its movement radius. For this purpose, fasten a cord at the lug of the pump cham-
ber (3) and anchor the other end of the cord at the edge or at the bottom of the pond.
Switching on / Switching off (C)
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug (13) prior to reaching into the water and commencing
work.
The unit switches on automatically when power connection is established.
Switching on: Plug the power plug (13) into the socket.
Switching off: Disconnect the power plug (13).
Maintenance and cleaning (D-I)
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug (C, 6) prior to reaching into the water and commencing
work.
Regular cleaning (D, E): Remove the filter basket (6) and the foam filter (7) from the unit, rinse with clean water and
reinstall.
Complete cleaning (F-H): Take the unit out of the water. Remove the air distributor (4) located beneath the pump
chamber (3). Press in the engagement lugs on three sides of the pump chamber (3) and remove the container (2).
Ensure that the air hose (9) does not slip off the injector (10). Remove the pump (10) and undo the union nut of the
injector (8). Clean all components using clean water and a brush.
Cleaning the pump (I): Open the pump cover (11) with the bayonet closure and remove the impeller (12). Clean all
components using clean water and a brush.
Reassembly: After cleaning the pump and the unit, reassemble in the reverse order.
Important: Route connection cable such that it cannot be pinched. Ensure that the air hose (G, 9) is routed without
kinks. The engagement lugs must audibly click when reassembling the pump chamber (3) and the container (2). Align
the air distributor (4) as shown in figure B.
Malfunctions
Malfunction
The unit is not operating
Insufficient delivery rate
No aeration
Unit switches off after a short running period
4
19722-01-14_SwimSkim USA.pdf 4
Cause
No mains voltage
Impeller blocked
Filter basket / foam filter soiled
Injector blocked
The aerating hose between the floating body
and the injector is kinked or disconnected
Water temperature too high
Remedy
Check mains voltage
Clean
Clean
Clean
Ensure secure fastening and avoid kinks in the
aerating hose
Note maximum water temperature of 95°F
(+ 35°C)