General Specifications

Dimensions (W x H x D) :
Approx. 120mm x 280mm x 25mm
Weight(without Battery) : 170g
Power Requirements : AAA Size Battery x 2
Battery Life : 160 hours ALKALINE Battery
Low Batteries Indication :
Voltage drops below operating voltage the
battery indicator will flash.
Maximum Conductor Size : coil size
Safety Standard :
EN61010-1, EN61010-2-032, EN61010-031
EN61326-1
CAT IV 600V, CAT III 1000V

Environmental Specifications

Indoor Use.
Pollution Degree : 2
Maximum operating altitude : 2000m (6562 ft)
Operating temperature & Relative Humidity :
0°C - 30°C, ≦80%RH
30°C - 40°C, ≦75%RH
40°C - 50°C, ≦45%RH
Storage temperature :
-20°C - 60°C, 0 to 80% RH (no batteries).
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C
Shock vibration : Sinusoidal vibration
MIL-PRF-28800F (5-55 Hz, 3g max.)
Drop Protection : 4 feet drop to hardwood on
concrete Floor

Electrical Specifications

Accuracy is given as ±(% of reading + counts
of least significant digit) at 23°C ± 5°C, with
relative humidity Less than 80% R.H.
Accuracy is specified for a period of one year
after calibration.
Max. output voltage: 4.5Vpeak
Position Error of Clamp:
Accuracy and position error assumes centralized
primary conductor at optimum position, no external electrical or
magnetic field, and within operating temperature range.
Distance from
Optimum (mm)
sFlex-10T
Error
15
±2.0%
25
±2.5%
35
±3.0%