Stanley S300 Mode D'emploi
Masquer les pouces Voir aussi pour S300:
Table des Matières
  • English

    • Italiano

      • Español

        • Português

          • Dutch

            • Deutsch

              • Norsk

                • Svenska

                  • Dansk

                  • Suomi

                    • Русский

                      • Polski

                        • Ελληνικά

                          • Magyar

                            • Čeština

                              • Slovenčina

                                • Latviešu

                                  • Eesti

                                    • Lietuvių

                                    • Română

                                      • Български

                                        • Türkçe

                                          • Hrvatski

                                            • Slovenščina

                                            Les langues disponibles
                                            • FR

                                            Les langues disponibles

                                            • FRANÇAIS, page 3

                                            Liens rapides

                                            S300
                                            STHT77407
                                            Stanley Stud Sensor 300
                                            The Stud Sensor 300 uses electronic signals to locate the center of studs, joists
                                            or live AC wires through drywall or other common building materials. Once
                                            the center of a stud has been detected in one pass across the surface, the
                                            Stud Sensor 300 gives a visual display and sounds an audible tone. A marking
                                            channel allows you to easily note the stud center and edges on the wall.
                                            The Stud Sensor 300 will not detect objects in concrete, mortar, block or brick
                                            work, carpeting, foil faced materials, metallic surfaces or ceramic tiles. The
                                            Stud Sensor 300 is not designed to locate non-ferrous or plastic objects such
                                            as pipes.
                                            Note: Read all instructions prior to operating the Stud Sensor 300 and DO NOT
                                            remove any labels from the tool.
                                            WARNING:
                                            Protect Your Eyes, Wear Safety Goggles.
                                            1
                                            77407
                                            • Marking Channel
                                            • Live Wire Warning LED
                                            • LCD Display
                                            • Activation Button
                                            • STUD or METAL / AC Mode Selection
                                            • METAL SCAN Mode
                                            • AC TRACKING Mode
                                            • Self-Calibration Complete
                                            REV A 12
                                            OPERATING INSTRUCTIONS
                                            Battery
                                            1
                                            Open door on back of unit and connect a 9 volt battery
                                            (not included) to clip. Put battery back into case and close
                                            back battery door.
                                            Note: Recommend to replace a new 9 volt battery
                                            when low battery - "Low Battery" will appear on the
                                            LCD.
                                            Usage
                                            Detecting Wood / Metal Studs
                                            2
                                            Hold the Stud Sensor 300 fl at
                                            against the surface, making fi rm
                                            contact.
                                            3
                                            Press in and hold the activation
                                            button. A series of tones will sound.
                                            Note: The unit cannot be moved before
                                            calibration is complete.
                                            "Ready" icon will appear on the LCD.
                                            during all of the following procedures.
                                            Note: Once the Activation button is
                                            released, the unit shuts off.
                                            10
                                            the activation button is pressed, move the Stud Sensor
                                            300 to a different location and try again. Releasing the
                                            activation button will turn off the sensor.
                                            • Live Wire Detected
                                            Note: While calibrating, the Stud Sensor 300 must not
                                            • Depth Detection Mode
                                            be placed directly over a stud, dense material such as
                                            • STUD Mode
                                            metal, or over a wet or newly painted area, or it will not
                                            properly calibrate.
                                            • Stud Location Graphic
                                            • Low Battery Indicator
                                            As it detects a stud, the unit will display the relative position of the stud
                                            on the screen.
                                            center, the "Center" icon will appear on
                                            the LCD and an audible tone will sound.
                                            Use the marking channel located at the
                                            top of the unit to mark the stud center.
                                            4
                                            When the unit is calibrated the
                                            5
                                            Keep holding the activation button
                                            If all segments of the LCD fl ash on and off when
                                            8
                                            Slide the Stud Sensor 300 slowly across the surface in a straight line.
                                            6
                                            7
                                            /
                                            When it detects the stud
                                            8
                                            Table des Matières
                                            loading

                                            Sommaire des Matières pour Stanley S300

                                            • Page 3 • Indicateur de pile faible • Auto-étalonnage terminé STHT77407 REV A 12 Détecteur de montant 300 Stanley MODE D'EMPLOI Faites glisser le Détecteur de Montant 300 doucement sur la surface Le Détecteur de Montant 300 utilise des signaux électroniques pour trouver Pile selon une ligne droite.
                                            • Page 4: Conseils D'utilisation

                                              à compter de la date d’achat. Le Détecteur de Montant 300 effectuera l'analyse à travers les matériaux de La responsabilité de Stanley dans le cadre de cette garantie se limite au construction courants, y compris : remplacement de l’appareil.

                                            Table des Matières