Stanley S200 Mode D'emploi
Masquer les pouces Voir aussi pour S200:
Table des Matières
  • Operating Tips
  • Important Safety Notice
  • Suggerimenti Per L'uso
  • Consejos para el Funcionamiento
  • Instruções de Funcionamento
  • Especificações
  • Bedieningsinstructies
  • Specificaties
  • Technische Daten
  • Spesifikasjoner
  • Viktiga Säkerhetsanvisningar
  • Specifikationer
  • Tekniset Tiedot
  • Технические Характеристики
  • Советы По Эксплуатации
  • Instrukcja Obsługi
  • Dane Techniczne
  • Οδηγιεσ Λειτουργιασ
  • Üzemeltetési Utasítások
  • Használati Tanácsok
  • Műszaki Adatok
  • Pokyny Pro Použití
  • Technické Údaje
  • Prevádzkové Pokyny
  • Ekspluatācijas NorāDījumi
  • Tehnilised Andmed
  • Instrucţiuni Importante de Siguranţă
  • Инструкции За Експлоатация
  • Kullanim Tali̇matlari
  • Upute Za Rukovanje
  • Savjeti Za Upotrebu
Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3

Liens rapides

S200
STHT77406
Stanley Stud Sensor 200
The Stud Sensor 200 uses electronic signals to locate the center of
studs, joists or live AC wires through drywall or other common building
materials. Once the center of a stud has been detected in one pass
across the surface, the Stud Sensor 200 gives a visual display and
sounds an audible tone. A marking channel allows you to easily note
the stud center and edges on the wall.
Note: Read all instructions prior to operating the Stud Sensor 200 and
DO NOT remove any labels from the tool.
WARNING:
Protect Your Eyes, Wear Safety Goggles.
1
77406
• Marking Channel
• Live Wire Warning LED
• LCD Display
• Activation Button
• Live Wire Detected
• Self-Calibration Complete
REV A 08
OPERATING INSTRUCTIONS
Battery
1
Open door on back of unit and connect a 9 volt
battery (not included) to clip. Put battery back into
case and close back battery door.
Note: Recommend to replace a new 9 volt
battery when low battery - "Low Battery" will
appear on the LCD.
Usage
Detecting Wood / Metal Studs
2
Hold the Stud Sensor 200 fl at
against the surface, making fi rm
contact.
3
Press in and hold the activation
button. A series of tones will
sound.
Note: The unit cannot be moved
before calibration is complete.
4
When the unit is calibrated the
"Ready" icon will appear on the
LCD.
5
button during all of the following
procedures.
Note: Once the Activation button
is released, the unit shuts off.
10
If all segments of the LCD fl ash on and off
when the activation button is pressed, move the
Stud Sensor 200 to a different location and try
again. Releasing the activation button will turn
• Stud Location Graphic
off the sensor.
Note: While calibrating, the Stud Sensor 200
must not be placed directly over a stud, dense
• Low Battery Indicator
material such as metal, or over a wet or newly
painted area, or it will not properly calibrate.
8
1
Slide the Stud Sensor 200 slowly across the surface in a straight
line. As it detects a stud, the unit will display the relative position
of the stud on the screen.
2
3
6
/
center, the "Center" icon will
appear on the LCD and an audible
tone will sound. Use the marking
channel located at the top of the
unit to mark the stud center.
4
≤ 3
Keep holding the activation
10
7
When it detects the stud
6
5
sec
10
2
8
7
Table des Matières
loading

Sommaire des Matières pour Stanley S200

  • Page 3 • Auto-étalonnage terminé STHT77406 REV A 08 Détecteur de montant 200 Stanley MODE D'EMPLOI Faites glisser le Détecteur de Montant 200 doucement sur Le Détecteur de Montant 200 utilise des signaux électroniques pour Pile la surface selon une ligne droite.
  • Page 4: Conseils D'utilisation

    L’étalonnage, les piles et l’entretien sont votre main libre à l’écart de l’appareil. à la charge de l’utilisateur. Lorsque la loi le permet, Stanley n'est pas responsable des dégâts accidentels ou indirects. Les agents de Remarque : L’épaisseur, la densité et le niveau d’humidité du CONSEILS D'UTILISATION Stanley ne peuvent pas modifi...

Table des Matières