6 ROUTINE MAINTENANCE

1
Replacement of lighted top cover bulbs (see figure 10) :
-
Remove the fixing screws placed in the upper part of the top
cover,
-
remove the lower part and replace the bulbs (using a 24-
28V 21W max bulbs).
-
Reassemble the top cover and replace the fixing screws.
2
Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication, worn
or damaged parts. Replace parts as needed with original spare
parts from the supplier.
IMPORTANT
Use gloves of a minimum PL 0-4 class (EN388).
6. 1 MAINTENANCE (TO BE CARRIED
OUT BY QUALIFIED SERVICE
PERSONNEL ONLY)
Montly: clean all internal components, primarily the condenser,
using compressed air, in order to remove dust.
To clean these internal parts, unplug the unit.
Condenser fins are very sharp. Use extreme caution when
cleaning.
ATTENTION
Verify the correct position of the cable before closing the
cabinet and before supplying electricity.
figure 10