Télécharger Imprimer la page

Operation; Checking The Sensor - Schon 67558-0101 Guide D'utilisation Et D'entretien

Publicité

Les langues disponibles

Les langues disponibles

Operation

1
Flushing and checking for leaks
IMPORTANT: After installation is completed, turn on the
hot and cold water supplies. Check for leaks. Do not lose
the gasket (1) in the hose.
Pull the hose assembly out of the spout and
remove the spray head by unscrewing it from
the hose in a counterclockwise direction. Be
sure to hold the end of the hose down into the
sink and turn the faucet to the warm position
where it mixes hot and cold water.
Flush the water lines for one minute. This ushes
away any debris that could cause damage to
internal parts. Check for leaks.
Re-tighten any connections if necessary, but do
not overtighten. Reinstall the spray head by hand
tightening it back onto the spray hose.
2

Checking the sensor

NOTE: Make sure the handle is open before using the
sensor.
Check to ensure the sensor is working properly.
Turn the handle (1) to the full on position, the
water will turn on. Then turn the handle (1) to
the full off position, the water will turn off.
Turn the handle (1) to the full on position again,
the water will turn on again, then move your
hand in the max 8 in. distance from the
sensor (2), as shown to test that the water will
turn off. Move your hand in the sensor area again
to turn the water on, then turn the handle (1) to
the full off position to turn the water off.
NOTE: Water will turn off automatically after 3 minutes.
1
0
3
min.
45
30
Max 8 in.
11
Please contact (800) 880-8164 for further assistance.
15
2
www.schonsimplymodern.com