Leuze BCL 92 SM 300 Mode D'emploi page 33

Masquer les pouces Voir aussi pour BCL 92 SM 300:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Baud rate
Data format
Service interface
(fixed data format)
Switching input/output
Degree of protection
VDE protection class
Housing
Weight
Dimensions
Ambient temp. (operation/
storage)
Relative humidity
Vibration
Shock
Electromagnetic compati-
bility
Conformity
Certifications
CAUTION
UL applications!
For UL applications, use is only permitted in LPS/Class 2 circuits in ac-
cordance with the NEC (National Electric Code).
BCL 92
4800 ... 57600 Bd
Data bits: 7, 8
Parity: none, even, odd
Stop bits: 1, 2
RS 232, 9600 Bd, 8 bit, no parity, 1 stop bit
<STX> Data <CR><LF>
2 switching inputs
+12 V DC ... +30 V DC
2 switching outputs
+10 V ... +30 V, 20 mA
IP54
III with SELV power supply unit
Diecast zinc
Approx 210 g
Net weight without con-
nection cable
See
2
+5 °C ... +40 °C / -20 °C ... +60 °C
Max. 90  % (non-condensing)
IEC 60068-2-6, test Fc
IEC 60068-2-27, test Ea
EN 61326-1:2013-01
CE, CDRH, UL
UL 60950-1, CAN/CSA C22.2 No.  60950-1-07
BCL 95
1 switching input 5 V DC
1 switching output
5 V ... 30 V, 20 mA
Approx. 210 g
EN
33

Publicité

Table des Matières
loading

Table des Matières