Ain King SEV24S Mode D'emploi page 3

Unité de puissance
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Supply from home
Hot (Black)
Ground (Green or Bare)
Figure 5
2.
Attach the wire compartment to the power unit with two of the provided #6 blunt tipped
screws (Figure 6).
Wire Compartment
Figure 6
SECTION 7
Finishing the Installation
1.
Remove any protective plastic adhered to the power unit.
2.
Turn switches to the OFF ( • ) position and restore power. Test that the light and the fan
are operating properly.
3.
If there is any vibration noise, check for the source and try to tighten fasteners, adjust
the tape to make a tighter connection or seal, or check that the hood collar damper, wall
damper or ceiling damper are opening properly.
SECTION 8
Operation
Controls
Your Range Hood is equipped with two rotary switches with one controlling the lighting and
the other controlling the exhaust fan blower. The light switch has three positions, High, Low,
and Off. The fan switch has four positions, Off, High, Medium, and Low (Figure 7).
Figure 7
SECTION 9
Maintenance
CAUTION:
SERVICE PANEL BEFORE SERVICING THE UNIT.
Filters
1.
Included with your unit are aluminum grease filters that should be washed at least once a
month. The filters are dishwasher safe and should be washed in a mild soap or detergent.
2.
To remove the filters, pull down on the handle tab until the filter releases from the unit. To
reinstall, slide tab at rear of filter into slot in the unit. While holding in handle of filter, lift
filter into place and release handle. The filter should snap securely into place (Figure 8).
6728012 Rev. O 4-17
Neutral (White)
From Hood
MAKE SURE POWER IS SWITCHED OFF AT
Figure 8
3.
If the grease filters become damaged, replace with the Air King Model SVGF-03 Grease Filters.
Changing the Lamp
1.
To remove/replace the light bulb, remove the
filters using the procedure listed above.
2.
Locate the lamp holder bracket mounted on
the back wall of the hood (Figure 9).
3.
Loosen the upper & lower wing nuts a few
turns by turning counter-clockwise (loosen
only, do not remove the nuts or bracket).
4.
Lower the bracket so the lamp protrudes
below the face of the hood.
5.
Remove the lamp by turning slightly counter-
clockwise and pulling out of the socket. Re-
place with a MR16 GU10 Base 50W maximum
Halogen lamp.
6.
Installation is the reverse of removal.
Fuse
To replace the fuse, turn the fuse cap located next to the wire connector counter clockwise
and pull out. Replace with a Bussman MDA 250-Volt, 5 Amp Max. fuse (models SEV28AB and
SEV30AB utilize a 3 Amp Max fuse). Reinstall the fuse back into the hood.
Cleaning
CAUTION:
CLEANSERS, ETC., AS THEY MAY DAMAGE THE RANGE HOOD.
1.
Clean your power unit with a mild detergent, such as dishwashing liquid, and dry with a soft
cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry before
restoring power. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
2.
The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates over time.
The fan is permanently lubricated and does not require oiling.
CALIFORNIA RESIDENTS ONLY:
WARNING:
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
WARNING:
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE REPRODUCTIVE
TOXICITY.
www.airkinglimited.com
Tab
Figure 9
DO NOT USE GASOLINE, BENZINE, THINNER, HARSH