Control Panel Functions - Helo T2 Manuel Produit

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
Installation and User's Manual Helo T2
4.2

Control panel functions:

General
-
The control panel is intended for installation outside the sauna room.
-
Maximum bathing time in monitored facility use is 18 hours. With timer control the maximum time is 12 hours,
after which there is a compulsory 6 hour break. The control panel gives an error message if 12 hours is
exceeded. The pause period can be reset from the control panel separately, for instructions see Settings –
Service – Settings – Reset pause timer. In private use the maximum on time for the sauna heater is 6 hours.
-
The available pre-set period for the 24h timer is 24 hours.
-
The control panel includes also a calendar function that can be used to turn the sauna heater ON on certain days
and at certain times. However, this function should not be utilized in monitored institutional use conditions.
-
There is a motion sensor in the front of the control panel. If the control panel senses no movement, it switches
to the screen saver mode to save energy. The activated functions will stay on.
-
The control panel is equipped with a key lock to prevent the misuse of the panel.
-
In accordance with the applicable regulations on electrical devices, only a qualified professional is allowed to
connect the sauna heater and the control panel to the power mains.
-
In accordance with the regulations concerning the sauna heaters, a door switch must be installed for use in
unsupervised conditions to prevent the remote switching on of the sauna heater (the calendar timer or the 24h
timer) while the sauna room door is open.
First time starting up / Restoring the factory settings:
Select the geographic region where the sauna heater is used. After this,
select the appropriate language from the menu using the arrow keys and press OK.
Next, set the time and the date. After each number selection, press OK.
Next, select the intended use of the sauna heater. Your choices are:
-
Supervised facility. Supervised conditions in a facility, such as an indoor
swimming pool,spa or health resort. The maximum
ON-time for the sauna heater is 18 hours.
The timers (calendar, 24h) are not available for turning on the sauna heater
-
Time controlled. Pre-set time to turn on the sauna heater. The maximum
ON-time for the sauna heater is 12 hours. The timers (calendar, 24h) are
available for turning on the sauna heater.
-
Private sauna use. Maximum on time for the sauna heater is 6 hours.
Using pre-set timer is possible. Using calendar timer is not possible.
Next, choose the length of the sauna bathing time. The selected ON-period for the sauna heater may be maximum
allowed or less, in other words, 0–18 hours, 0–12 hours or 0–6 hours, depending on the type of use
Next, choose the use of the door switch. According to the electric device regulations, a Door switch must be
installed and switched ON in circumstances where the sauna heater can be turned on remotely and/or on a
timer, and where no pre-checking of the sauna is performed. Before the remote use, as indicated above, is
possible, the door of the sauna room must be closed and the appropriate option checked in the control panel
as needed. This will make it possible to turn on the sauna heater.
7
Select Region
Europe
USA
Other Regions
OK
00:00
OK
Facility type
Supervised facility
Time controlled
Private factility
OK

Publicité

Table des Matières
loading

Produits Connexes pour Helo T2

Table des Matières