SAFETY NORMS AND CLEANING RECOMMENDATIONS.
- Check that the mains voltage coincides with that indicated on the characteristics plate.
- The electricity supply must be earthed and have a neutral line.
- The unit must be installed in accordance with the national regulations for electrical installations.
- The unit must be placed so that the CETAC attachment plug be accessible.
- Before manipulating the connection, all supply circuits must be disconnected.
- Do not place the cable in front of the air outlet or in contact with the walls while the blower heater is operating.
- The blower heater must not be placed directly below a power socket.
- The minimum distance of curtains and other combustible materials from the hot air output of the blower heater is 50 cm.
- Never touch the controls of the blower heater with wet hands.
If the blower heater is operated as a mobile apparatus: Do not use near a bath, shower or swimming-pool.
If the blower heater is operated as a fixed apparatus: It must be placed so as to prevent contact with any person that is in the bath or shower.
- Do not cover the blower heater with objects that prevent the free circulation of air.
- Keep the air inlet and outlet grills clean.
- If the feed cable of the air heater is broken, only can be remplaced by Electricfor, S.A.
- If you wish to add an extention cable to ANB, only use those suppled by Electricfor S.A. or someone of theirs authorised distributors.
- Any dismantling of the appliance carried out other than by an authorised Electricfor, S.A. distributor will cause the guarantee to be null and void.
INSTALLATION NORMS.
FOR MOBILE USE:
- The blower heater should be installed a minimum of 200 mm from the walls .
- The blower heater can be installed directionning the hot air towards a required zone, by turning the unit vertically, there are 5 differents fixed positions
with a upper limit of + 20° and a lower limit of - 54° upon the horizontal plane. See Figure ner 3 (To fix diferents position see USER INSTRUCTIONS).
FOR WALL INSTALLATION:
- There must be sufficient space around the unit for good air circulation. Respect the distances indicated in Figure n
- The blower heater should be fixed to the wall by means of the accesory for wall fixation (code 129098000 for ANB3'6, ANB6 and ANB9; code
129130000 for ANB12 and ANB17) supplied for Electricfor S.A. or their distributor. This accesory has a 180° horizontal turning support.
Figure n
er
CEILING
0
°C
Min.
200 mm
Recommended height
according Table nº 2
GROUND
WALL INSTALLATION RECOMMENDATIONS:
We can see at Table n
2 recommended installation heights and approximate sweep length.
er
(*) The ANB3'6, ANB3'6SN and ANB3'6B air heaters are a mobile unit or a fixet unit mounted at 1'8
m minimum height.
This manual is valid for the apparatuses of standard range.
The special manufactures can have variations with respect to the indicated thing in this manual
ORIENTABLE ELECTRICAL AIR
HEATER ANB MOBILE OR FIXED.
5. Wall installation of ANB.
CEILING
Min. 200 mm
Mín. 200 mm
No cubrir
Ne pas couvrir
Do not c ov ert
Non coprire
Figure n
Approximate sweep length.
Sweep length
Installation recommendations.
Unit
ANB3,6
ANB3,6SN
ANB3,6B
ANB6
ANB6SN
ANB9
ANB12
ANB17
C/. Ca n'Alzamora, 34-36 - 08191 RUBÍ
Tels. +34 93 586 00 45
E-mail: electricfor@electricfor.com Internet: http://www.electricfor.com
NTC - 9804
Pag 12
Ed 17
26/06/06
4.
er
6.
er
Lower limit
Sweep
-54 °
zone
Table n
2.
er
Recommended
Sweep
height
length
2 m
2,5 m
2 m
4,2 m
2,5 m
4,2 m
3 m
7,2 m
3 m
7,2 m
(Barcelona)
ESPAÑA
Fax
+34 93 586 00 48

Publicité

loading

Ce manuel est également adapté pour:

Anb3,6snAnb3,6bAnb6Anb6snAnb9Anb12 ... Afficher tout