Thetford Spinflo 160 Serie Mode D'emploi Et Consignes D'installation page 16

Plaque chauffante encastree de cuisine
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Fixing – All Models
All models are fixed to the worktop by clamps from underneath the appliance – see pages 7,8 &
9 for worktop cutout details and page 10 for clamping method.
Gas Connection
A 3/8 in NPT to 3/8 in Dia Flared pipe fitting provides the gas inlet connection on the underside
of the appliance. It is recommended that the appliance be connected by copper tubing, a rubber
or hose connection must not be used. After connection the appliance must be tested for
soundness.
This appliance is suitable for use on :
It is important that the regulator should be set to the correct pressure for the type of gas being
used. Excessive pressure must not be permitted.
If the flame on the burners has a tendency to lift, it is probable that the line pressure is too great.
Should there be excessive yellow tips (resulting in sooting) then it is probable that the line
pressure is too low. In either case, do not use until the line pressure has been checked.
The burners on this appliance have fixed aeration and no adjustment is necessary.
Models with 12Volt Spark Ignition
Connection to the 12volt electrical supply of the recreational vehicle is made via the spade
terminals located on the spark ignition generator. A supply cord terminating in sheathed spade
connectors is recommended.
All Models – Pressure Testing
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of the system at test pressures in excess of
½ psi (3.5kPa).
The appliance must be isolated from the gas supply system be closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less the ½ psi (3.5kPa).
When satisfied with the appliance and after instructing the user on the correct method of
operation, these instructions MUST be left with the appliance. If the appliance fails to operate
correctly after all checks refer to the authorised service provider in your area.
IMPORTANT
• After installation the appliance MUST be tested for soundness
• Test ALL burners on high and low flame for flame stability.
• The gas supply input pressure MUST NOT rise or fall significantly from nominal
when ALL appliances connected to the supply are operated simultaneously.
3/8 in NPT to 3/8 in Dia Flared pipe
Propane Gas Only
Max regulator inlet pressure
Regulator supply pressure
Manifold working pressure
11 in wc (27.4mbar)
½ in psi (34.5mbar)
12 in wc (30.0mbar)
11 in wc (27.5mbar)
16

Publicité

Table des Matières
loading

Table des Matières