Plumbing And Setting The Water Level - Skuttle Indoor Air Quality Products 60 Serie Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Plumbing and Setting the Water Level

NOTE: Use copper tubing only to plumb this humidifier.
1.
Select the nearest cold water pipe and install the saddle connector and nee-
dle valve (provided) by following the instructions supplied with the valve.
WARNINg: Do not use any line connected to an air conditioner.
2.
Lightly clean the tubing ends with fine sandpaper before making connec-
tions.
3.
Uncoil the copper tubing and con-
nect one end to the saddle valve.
Use
the
found in the self-piercing saddle
valve parts bag.
Place the brass compression
nut over the tubing, then slide
the brass ferrule over the
tubing.
Fully insert the tubing into the
saddle valve fitting and tighten
the compression nut. (Do
not
over-tighten;
tightness should prevent leaking.)
Thoroughly flush the supply tubing after attaching it to the saddle valve.
This will clear the line of debris which could block water flow at the float
valve.
4.
Route the tubing to the humidifier float valve, keeping the tubing away from
sharp edges.
5.
Connect the remaining end of the tubing to the humidifier float valve.
6.
Open the saddle valve so that the water flows slowly and gently into the
water pan.
7.
Prior to mounting, adjust the humidifier's water level by following these in-
structions:
Set the humidifier reservoir on a level surface.
Allow the unit to fill until the float valve shuts off the incoming flow of
water. (The water should be 2-3/8" deep, plus or minus 1/8". If it is not,
further adjustment will be necessary.)
compression
fittings
moderate
11

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

60-1F60-160-2F60-2