A terminating resistor can be inserted using the DIP Switch (4-bit) on the rear of the RS-422/485 type. Factory default
settings are all set to "OFF" (no terminating resistor).
Important: GND (SG) must not be connected to ground Shield.

Entering Offline mode when Operating

At Power ON
Touch the upper right corner or upper left corner (within 40 pixels of the edges) of the panel for at least 3 seconds soon after the
startup screen is displayed.
RS422/RS485 terminal Block
Label
Meaning
CSB
Send Possible B (-)
CSA
Send Possible A (+)
ERB
Data Terminal Ready B (-)
ERA
Data Terminal Ready A (+)
SG
Signal Ground
RDB
Receive Data B (-)
RDA
Receive Data A (+)
SDB
Send Data B (-)
SDA
Send Data A (+)
1
2
3
4
5
6
7
8
9
Quick Start Guide SCAIME:
11
NUSG-eNodTouch-MS-FE_196776_D.docx

Important:

If the distance
between eNodTouch and
eNod4 is short (<1m),
don't use terminating
resistor on the
eNodTouch side as well
as the eNod4 side.