A binary LED code helps determining the position of the rotary
switch.
After changing the position of the rotary switch, the LED's will
blink during 4 seconds as follows:
Switch
LED
position
Float
0
1
2
3
4
5
6
7
Thereafter, normal indication resumes, as described below.
3.6 LED's
LED indication:
 permanent on
 blinking
 off
Regular operation
Bulk (*1)
Absorption
Automatic equalisation (*2)
Float
Note (*1): The bulk led will blink briefly every 3 seconds when the system
is powered but there is insufficient power to start charging.
Note (*2): Automatic equalisation is introduced in firmware v1.16
Fault situations
Charger temperature too high
Charger over-current
Charger or panel over-voltage
Internal error (*3)
Note (*3): E.g. calibration and/or settings data lost, current sensor issue.
LED
Abs
1
1
0
0
0
1
0
1
1
0
1
0
1
1
1
1
LEDs
Bulk
LEDs
Bulk
LED
Bulk
frequency
1
1
0
1
0
1
0
1
Absorption
Absorption
Blink
fast
slow
slow
slow
slow
slow
slow
slow
Float
Float
7