Mechanical Adjustments - GEZE GC 304 R Mode D'emploi

Masquer les pouces Voir aussi pour GC 304 R:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1
OPENING THE SENSOR
Before fi xing
After fi xing
2
MOUNTING & WIRING
Do not touch electronical
Avoid vibrations.
parts.
Wall mounting above sliding or
Mounting on door axis (swing doors)
revolving door
1
2
Apply the mounting template.
Connect the wires accordingly:
Drill 1 hole for the cable and
1 - BROWN - POWER SUPPLY
2 - GREEN - POWER SUPPLY
pull it through.
3 - WHITE - COM
Drill 2 holes for the screws.
4 - YELLOW - NO
5 - YELLOW - NC
Do not cover the sensor.
Avoid proximity to neon
lamps or moving objects.
Ceiling mounting in front of door
(sliding, revolving or swing doors)
3
Position the
cable as indicated.
Fix the sensor fi rmly.
or
3

MECHANICAL ADJUSTMENTS

2.2 m
4 m x 2 m (wide)
1
2.2 m
Adjust the lateral antenna
angle.
4
SETTINGS
(by remote control or push buttons)
XXS
XS
S
FIELD SIZE
IMMUNITY FILTER
low
normal
DETECTION MODE
bi
uni
OUTPUT
A
P
CONFIGURATION
HOLD-OPEN TIME
0.5 s
1 s
2 s
MOUNTING
< 3 m
< 3 m
> 3 m
> 3 m
HEIGHT
DOOR CONTROL
auto
open
FACTORY VALUES
RESETTING TO FACTORY VALUES:
FIELD SIZE
... S,
2.2 m
2 m x 2.5 m (narrow)
2
2.2 m
Adjust the vertical antenna
angle.
>
>
>
>
L
XL
XXL
high
>
>
>
>
>
highest
bi = two-way detection; uni = one-way detection towards sensor
uni
uni
PRM &
uni PRM = one-way detection also of people with reduced mobility
PRM
AWAY
AWAY
uni AWAY = one-way detection away from sensor
A = active output (NO-contact)
P = passive output (NC-contact)
3 s
4 s
5 s
6 s
7 s
8 s
9 s
open = the sensor detects constantly. The LED is ON.
closed
closed = the sensor is in standby and does not detect. The LED is OFF.
OR
> 2 seconds
,
L
XS
XXS
...
+
XXL
XL
,
,

Publicité

Table des Matières
loading

Table des Matières