Operation
• The switching station US-16 may only be connected to 230 V AC/50 Hz.
• Operate only inverters with safe electrical separation (galvanic separation) between input circuit
(battery voltage) and output circuit (230 V).
• Before installation ensure that the inverter output as well as 230 V AC mains supply are voltage free
and equipped with a safety lock system to prevent unintentional start of the device.
• Ensure that the connection cables are connected properly and have good contact, as loose contacts
may cause smoldering fire.
• Do not connect the neutral conductor on the consumer side to earth or protective earth conductor;
as the consumer sockets in particular have no protective multiple earthing (i.e. connection of
PE­grounding wire with the neutral connector).
• The cross sections of the used cables must be selected and secured in compliance with applicable law.
• It is not permissible to use the device for three-phase current.
INSTALLATION
The installation should only be carried out by persons having relevant professional skills. If there is any
doubt, always contact an authorized expert. Use the supplied clamps to connect the protective earth
INSTALLATION
conductor. If the inverter has no earth connection, the battery terminal which is connected to earth must
The installation should only be carried out by persons having relevant professional skills. If there is any doubt, always
be connected to the protective earth conductor.
contact an authorized expert. Use the supplied clamps to connect the protective earth conductor.
If the inverter has no earth connection, the battery terminal which is connected to earth must be connected to the
protective earth conductor.
Attention! Before installation ensure that inverter output as well as 230 V AC mains
!
supply are voltage free and equipped with a safety lock system to prevent unintentional
Attention! Before installation ensure that inverter output as well as 230 V AC mains supply are voltage free
start of the device.
and equipped with a safety lock system to prevent unintentional start of the device.
Connection elements:
Connection elements:
1
i
The AC2 input has the higher priority; i.e. when there is voltage at both inputs,
The AC2 input has the higher priority; i.e. when there is voltage at both inputs,
the consumer is fed over the AC2 input.
the consumer is fed over the AC2 input.
Connection version 1:
The 230 V AC mains is connected to the AC2 input (higher priority).
I.e. the battery is spared and the inverter is simultaneously protected against external voltage.
Only if there is no current on AC2, AC1 input switches to power supply by means of the inverter.
More information at www.ivt-hirschau.de
400033-BA-Umschaltstation-US16.indd 7
2
3
2.
1.
3.
1.
Input AC1: 230 V AC, 50 Hz, max. 16 A
2.
Input AC2: 230 V AC, 50 Hz, max. 16 A
1
Input AC1: 230 V AC, 50 Hz, max. 16 A
2
Input AC2: 230 V AC, 50 Hz, max. 16 A
3.
Fuse: T 16 A / 250 V
3
Fuse: T 16 A / 250 V
4.
Output OUT: 230 V AC, 50 Hz, max. 16 A
4
Output OUT: 230 V AC, 50 Hz, max. 16 A