The electrical power to the oven branch circuit must be shut off while
line connections are being made.
Do not use an extension cord with this appliance.
Electrical ground is required on this appliance. The free end of the green
wire (the ground wire) must be connected to a suitable ground. This
wire must remain grounded to the oven.
If cold water pipe is interrupted by plastic, non metallic gaskets, union
connections or other insulating materials, DO NOT use for grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in
the NEUTRAL or GROUNDING circuit could result in an electrical shock.
Check with a quali ed electrician if you are in doubt as to whether the
appliance is properly grounded.
Failure to do so could result in death, re or electric shock.
Electrical Connection
To properly install your oven, you must determine the type of electrical connection
you will be using and follow the instructions provided for it here.
Oven must be connected to the proper electrical voltage and frequency as
speci ied on the model/serial number rating plate. The model/serial number
rating plate is located under the control panel on single ovens. All models are
dual rated, and designed to be connected to either 120/208V or 120/240V AC,
60Hz, 3-wire or 4-wire, single-phase power supply.
Style
Single Oven
Install a suitable conduit box (not furnished). An appropriately sized, UL conduit
connector must be used to correctly attach the conduit to the junction box.
IMPORTANT: Local Codes may vary; installation electrical connections and
grounding must comply with all applicable local codes.
WARNING
Electrical Shock Hazard
Voltage and
Amps
Frequency
240V, 60 Hz
20.0A
208V, 60 Hz
17.4A
Electric Oven
Circuit Required
25 Amp Circuit
20 Amp Circuit