Installation Instructions
TEMPERATURE & PRESSURE RELIEF VALVE
A discharge line should be installed and exit only 6 inches above, or at any
distance below, and should not come in contact with any live electrical part.
The T&P discharge opening must not be blocked or reduced in size under any
circumstances.
IMPORTANT: Failure to provide dielectric insulation may result in premature
tank or nipple failure and may void your warranty. The T&P valve is for
servicing and the valve should be in the open position when the water
heater is in operation. DO NOT APPLY HEAT DIRECTLY TO INLET OR OUTLET
CONNECTIONS.
Installed
3/4 Inch
T&P Valve
Installing the T&P Valve Discharge Pipe:
1. Must NOT be smaller in diameter than the outlet diameter of the valve, or have
any reducing couplings.
2. Must NOT be plugged or blocked.
3. Must be made of suitable material for hot water.
4. Must not be over 15 inches in length.
5. Must not have more than two elbows.
6. Must terminate at an adequate drain.
7. Must not have a shut off valve between relief valve and tank or relief valve and
termination of discharge.
PLEASE NOTE: MINI TANKS ARE FOR INDOOR PERMANENT INSTALLATIONS ONLY.
AND ALL AIR IS
REMOVED.THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
12
Support: Support.Eccotemp.com
THE FUTURE OF EFFICIENCY
Free Standing on Floor
BEFORE POWERING THE WATER HEATER, BE SURE THAT THE SYSTEM IS COMPLETELY FILLED WITH WATER
Shop Online: Eccotemp.com
No more than 2
elbows.
10.9"
THE FUTURE OF EFFICIENCY
15"
No more than 15 inches
ESH 2.5
combined length.
Store Locator: Eccotemp.com/locator
ESH 2.5 = 10.9 Inch
ESH 4.0 = 12.5 Inch
Wall Mounte