INSTALLATION

Physical Installation

High voltages capable of causing severe injury or death by electrical
shock are present in this unit.
Disconnect all power before installing the Capacitor Kit, servicing the pump, or servicing the
control panel.
The included run capacitor, start capacitor, and potential relay must be installed as shown in the
start/run circuitry diagram.
A suitable ground must exist for all pump and power connections.
Determine if the components are being installed in a panel or enclosure that has been previously
wired for a split-phase, capacitor start/capacitor run motor using similar components. If so, verify
that the wiring is correct and that any other components, e.g., circuit breakers, contactors, etc., are
of the proper electrical rating.
If not, the panel or enclosure may require rewiring by a qualified electrician or technician. It is rec-
ommended that the components be installed in a NEMA 4X rated enclosure.
Prior to supplying power or operating pump, check the following:
Inspect all wiring inside the control panel or enclosure for correct connection.
Inspect all wiring and components for damage and the presence of contaminants.
Make sure no wires will be pinched when the panel door or enclosure is closed.
Check that there is no moisture or debris in the control panel or enclosure.
Verify that the pump is correctly installed in the sump or basin.
Make sure no person is near the inlet or touching the pump.
For pump operation, refer to the IGP-A Series or IGP-M Series Owner's Manual. All electrical work
should be performed with strict adherence to the National Electrical Code, and all state or provin-
cial and local codes.
Start/Run Circuitry Diagram
INSTALLATION
Physical Installation
3