Extension Cords; Transporting - Westinghouse WGen5300v Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
Wattage Reference
Tool or Appliance
Incandescent Lights
(4 Quantity x 75 Watts)
TV (Tube Type)
Sump Pump (1/3 hp)
Refrigerator or Freezer
Well Pump (1/3 hp)
Furnace (1/2 hp)
Radio
Drill (3/8", 4 amps)
Circular Saw
(Heavy Duty, 7-1/4")
Miter Saw (10")
Table Saw (10")
*Wattages listed are approximate. Verify actual wattage.

EXTENSION CORDS

Asphyxiation hazard. Extension cords running directly
into the home increase the risk of carbon monoxide
poisoning through any openings. If an extension cord
running directly into your home is used to power indoor
items, there is a risk of carbon monoxide poisoning to
people inside the home. ALWAYS use battery-powered
carbon monoxide detector (s) that meet current UL 2034
safety standards when running the generator. Regularly
check the detector (s) battery.
Asphyxiation hazard. When operating the generator with
extension cords, make sure the generator is located in
an open, outdoor area, far away from occupied spaces
with exhaust pointed away.
Fire and electrocution hazard. NEVER use worn or
damaged extension cords. Damaged or overloaded
extension cords could overheat, arc, and burn resulting
in death or serious injury.
Before connecting an AC appliance or power cord to the
generator:
• Use grounded 3-prong extension cords, tools, and
appliances, or double-insulated tools and appliances.
• Make sure the tool or appliance is in good working
order. Faulty appliances or power cords can create a
potential for electric shock.
• Make sure the electrical rating of the tool or appliance
does not exceed the rated power of the generator or the
receptacle being used.
16 | Westinghouse Outdoor Power Equipment, LLC
Estimated
Estimated
Running
Starting Watts*
Watts*
300
0
300
0
800
1300
700
2200
1000
2000
800
2350
200
0
440
600
1400
2300
1800
1800
2000
2000
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for
outdoor use that are rated for the electrical load.

TRANSPORTING

Weight hazard. ALWAYS have assistance when lifting
the generator.
• Allow the generator to cool a minimum of 30 minutes
before transporting.
• Replace all protective covers on the generator control
panel.
• Only use the generator's fixed frame to lift the unit or
attach any load restraints such as ropes or tie-down
straps. DO NOT attempt to lift or secure the generator
by holding onto any of its other components.
• Keep the unit level during transport to minimize the
possibility of fuel leakage or, if possible, drain the fuel
or run the engine until the fuel tank is empty before
transport.

Publicité

Table des Matières
loading

Table des Matières