Balluff BAE00T3 Notice D'utilisation page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
BAE PD-XE-005
Calibration box
Status diagram/calibration procedure
1
Fig. 2:
Status diagram
Statuses
Description
Status 1
The calibration box is connected to the supply voltage.
Startup
Status 2
The sensor system is connected to the calibration box.
Sensor detected
Status 3
Pressing the button for longer than 5 seconds.
Error establishing com-
Unable to establish communication to the sensor.
munication
Calibration box returns to status 2.
(e.g. insufficient supply voltage)
Status 4
Pressing the button for longer than 5 seconds.
Communication establis-
Communication established successfully.
hed successfully
Status 5
Pressing the button for 1 second.
Programming error
Error during programming.
Calibration box returns to status 4.
Status 6
Pressing the button for 1 second.
Programming successful
Programming successful.
Calibration box returns to status 4.
Status 7
Pressing the button for longer than 8 seconds.
Reset
The sensor system returns to its delivery state.
Calibration box returns to status 2.
Status 8
Idle time since last action is more than 2 minutes.
Communication inter-
Communication is interrupted.
rupted
Calibration box returns to status 2.
Status 9
Remove the sensor system.
Remove sensor
Calibration box returns to status 1.
Status 10
All programmable parameters were programmed successfully
Programming successful
(see operating instructions for the respective sensor system).
Calibration box returns to status 2.
6
2
4
3 / 8
5
9
7 / 10
Status LED Error LED
Illuminated
Illuminated
Illuminated
Off
Illuminated
Quick
flashing
Slow
Off
flashing
Illuminated
Quick
flashing
Quick
Off
flashing
Illuminated
Off
Illuminated
Quick
flashing
Illuminated
Illuminated
Illuminated
Off
english
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bae pd-xe-005

Table des Matières