Section 6 − Operation; Front Panel Controls - Red-D-Arc Welderentals EXTREME 360 Mode D'emploi

Table des Matières

Publicité

6-1. Front Panel Controls

1
Power Switch
.
The fan motor is thermostatically
controlled and only runs when cooling is
needed.
2
Voltmeter
3
Ammeter
4
V/A (Voltage/Amperage) Adjustment
Control
5
Mode Switch
The Mode switch setting determines both the
process and output On/Off control (see Sec-
tion 6-3).
For Air Carbon Arc (CAC-A) cutting and goug-
ing, place switch in Stick position. For best re-
OM-229 409 Page 24
SECTION 6 − OPERATION
sults, place Arc Control in the maximum posi-
tion.
6
Remote 14 Receptacle
For remote control, make connections to
Remote 14 receptacle. In TIG and Stick
modes, remote control is a percent of V/A
Adjust control setting (value selected on V/A
Adjust is maximum available on remote). In
MIG modes, remote control provides full
range of unit output regardless of V/A Adjust
control setting.
7
Arc Control
Control adjusts Dig when Stick or CC mode is
selected on mode switch. When set towards
minimum, short-circuit amperage at low arc
voltage is the same as normal welding
amperage.
2
6
When set towards maximum, short-circuit
amperage is increased at low arc voltage to
assist with arc starts as well as reduce stick-
ing while welding.
Select setting best suited for application.
Control adjusts inductance when MIG or
V-Sense Feeder position is selected on the
mode switch. Inductance (0−100%) deter-
mines the "wetness" of the weld puddle. When
set towards maximum, "wetness" (puddle
fluidity) increases.
For self-shielding wires (FCAW), adjust Arc
Control to FCAW setting.
When Pulsed MIG or one of the TIG modes is
selected, this control is not functional.
3
5
4
FCAW
7
1
Ref. 803 692-B / Ref. 239 083-A

Publicité

Table des Matières
loading

Table des Matières