Télécharger Imprimer la page

Electrical Works - Toshiba RAS-B07J2AVSG-E Manuel D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
Model
Power source
Maximum running current
Circuit breaker rating
Power supply cable
Connecting cable
Indoor unit
Wiring of the connecting cable can be carried out without removing the
front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local cords) into the pipe hole
on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 20 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it tightly
with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor
unit.
Air inlet grille
Screw
How to install the air inlet grille on the indoor
unit
• When attaching the air inlet grille, the contrary of the removed operation is
performed.

ELECTRICAL WORKS

ELECTRICAL WORKS
RAS-B07J2KVSG-E RAS-B10J2KVSG-E RAS-B13J2KVSG-E
4.50A
10A
H07RN-F or 60245 IEC66 (1.5 mm
Front panel
Cord clamp
Screws
Terminal cover
50Hz, 220 – 240 V Single phase
6.75A
7.50A
10A
10A
2
or more)
Outdoor unit
1. Remove the valve cover, the electric parts cover and the cord clamp from
the outdoor unit.
2. Connect the connecting cable to the terminal as identifi ed by the
matching numbers on the terminal block of indoor and outdoor unit.
3. Insert the power cord and the connecting cable carefully into the terminal
block and secure it tightly with screws.
4. Use vinyl tape, etc. to insulate the cords which are not going to be used.
Locate them so that they do not touch any electrical or metal parts.
5. Secure the power cord and the connecting cable with the cord clamp.
6. Attach the electric parts cover and the valve cover on the outdoor unit.
12
RAS-B16J2KVSG-E
9.50A
15A
H07RN-F or 60245 IEC66
(2.5 mm
2
or more)
Terminals block
Valve cover

Publicité

loading