S+S Regeltechnik HYGRASREG KW Mode D'emploi

Masquer les pouces Voir aussi pour HYGRASREG KW:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6002-6400-2011-000 26400-2014 01 ⁄ 2014
KW
® 
HYGRASREG
TW
® 
HYGRASREG
D
Bedienungs- und Montageanleitung
Kondensationswächter KW und
Taupunktwächter TW,
incl. Spannband ⁄ mit abgesetztem Fühlerkopf,
mit aktivem ⁄ schaltendem Ausgang
G
Operating Instructions, Mounting & Installation
Condensation control switches KW and
dew point control switches TW
including strap ⁄with detached sensor head,
with active ⁄ switching outputs
F
Notice d'instruction
Contrôleur de condensation KW et
contrôleur de point de rosée TW,
y compris collier de serrage ⁄ avec sonde déportée,
avec sortie active / en tout ou rien
r
Руководство по монтажу и обслуживанию
Реле контроля конденсации KW и
pеле контроля точки росы TW,
вкл. хомут ⁄ с вынесенной чувствительной головкой,
с активным ⁄ релейным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
KW ⁄ TW - Rohr
mit Spannband
KW ⁄ TW - Pipe
including strap
KW ⁄ TW - tube
y compris collier
de serrage
KW ⁄ TW - для труб
с хомутом
KW - Wand
ohne Spannband
KW - Wall
without strap
KW - mur
avec collier
de serrage
KW - настенный
без хомута
KW ⁄ TW - extern
mit abgesetzten
Fühlerkopf
KW ⁄ TW - external
with detached
sensor head
KW ⁄ TW - externe
avec sonde
déportée
KW ⁄ TW - наружный
с вынесенной
чувствительной
головкой

Publicité

Table des Matières
loading

Sommaire des Matières pour S+S Regeltechnik HYGRASREG KW

  • Page 1 KW ⁄ TW - externe avec sonde déportée KW ⁄ TW - наружный с вынесенной чувствительной головкой S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄ GERMANY You have bought a German quality product.
  • Page 2 D G F r ®  HYGRASREG ®  HYGRASREG Maßzeichnung KW ⁄ TW - Rohr KW ⁄ TW - Pipe Dimensional drawing KW ⁄ TW - tube Plan coté KW ⁄ TW - для труб Габаритный чертеж KW - Wand KW - Wall KW - mur KW - настенный...
  • Page 3: Technische Daten

    HYGRASREG ® ® Der Kondensationswächter HYGRASREG KW wird auf Kühldecken, Kühl- ⁄ Kalt wasser- Schaltbild KW - W leitungen oder auf gekühlten Flächen montiert. Er erfasst die Betauung zuverlässig mit seinem Feuchte- und Temperatursensor (keine Leit fähig keits messung) und liefert Schaltpunkt ca.
  • Page 4 HYGRASREG ® ® Der Taupunktwächter HYGRASREG TW wird auf Kühl- ⁄ Kaltwasserleitungen oder Schaltbild TW - W auf kühlen Flächen montiert. Er erfasst die Betauung zuverlässig mit seinem Einstellung min. max. Feuchte- und Temperatursensor (keine Leitfähigkeitsmessung) und liefert dank seiner Schaltpunkt 100% Mess methode, der prodynamischen Querkonvektion, ein exaktes Messergebnis.
  • Page 5 Wichtige Hinweise – Dieses Gerät darf nur in schadstofffreier, nicht kondensierender Luft, ohne Über- oder Unterdruck am Sensorelement eingesetzt werden. – Bei Aussen- und Kanalfühlern schützt der Sinterfilter des Sensorelementes den Feuchtesensor vor eventuellen Staub belastungen. Dieser Filter sollte bei Verunreinigung ⁄ Verschmutzung regelmäßig gewartet werden. –...
  • Page 6: Technical Data

    HYGRASREG ® ® The condensation control switch HYGRASREG KW is installed on cooling ceilings, Schematic diagram KW - W on cooling or coldwater piping, or on cooled surfaces. It reliably detects formation of condensation by means of its humidity and temperature sensor (no conductivity Switchpoint ca.
  • Page 7 HYGRASREG ® ® The dew point control switch HYGRASREG TW is installed on cooling ceilings, on cooling Schematic diagram TW - W or coldwater piping, or on cooled surfaces. It reliably detects formation of dew by means Switchpoint min. max. of its humidity and temperature sensor (no conductivity measurement) and, thanks to setting 100%...
  • Page 8 General notes – This device must only be used in non-precipitating air without above-atmospheric or below-atmospheric pressure at the sensor element. – On outdoor and duct sensors, the sinter filter of the senor element protects the humidity sensor against potential dust exposure. In case of pollution ⁄...
  • Page 9: Caracteristiques Techniques

    HYGRASREG ® ® Le contrôleur de condensation HYRASREG KW est monté sur des plafonds frigori- Schéma de raccordement KW - W fiques et des conduites frigorifiques ⁄ d'eau froide ou des surfaces réfrigérées. Il mesure la condensation avec une grande fiabilité, à l'aide de son capteur d'humidité Switchpoint et de température (pas de mesure de conductivité).
  • Page 10 HYGRASREG ® ® Le contrôleur de point de rosée HYGRASREG TW est monté sur des plafonds frigorifiques et Schéma de raccordement TW - W des conduites frigorifiques ⁄ d'eau froides. A l'aide de son capteur d'humidité et de température Switchpoint min.
  • Page 11: Généralités

    Généralités – Cet appareil ne doit être utilisé que dans un air non pollué, sans risque de condensation, sans risque de surpression ou dépression sur l’élément sensible. – Dans le cas des sondes extérieures et des sondes pour montage en gaine, le filtre fritté de l’élément sensible protège la sonde d’humidité contre la pénétration des particules de poussières.
  • Page 12: Технические Данные

    HYGRASREG ® ® Реле контроля конденсации HYGRASREG KW монтируется на трубах холодного ⁄ Схема подключения KW - W горячего водоснабжения или на охлажденных поверхностях. Датчик влажности и температуры (проводимость не измеряется) надежно контролирует образование Switchpoint конденсата и благодаря особому методу измерения с высокоэффективной поперечной ca.
  • Page 13 HYGRASREG ® ® Датчик HYGRASREG TW монтируется на трубах холодного ⁄ горячего водоснабжения или на Схема подключения TW - W охлажденных поверхностях. Датчик влажности и температуры (проводимость не измеряется) Switchpoint min. max. надежно контролирует образование конденсата и благодаря особому методу измерения с setting 100% высокоэффективной...
  • Page 14: Напряжение Питания

    Указания к продуктам – Прибор допускается применять только в воздухе без конденсата и вредных веществ, при отсутствии пониженного или повышенного давления вблизи чувствительного элемента. – В случае датчиков для наружной и канальной установки защита чувствительного элемента датчика влажности от возможного скопления пыли обеспечи- вается...
  • Page 15 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r ®  HYGRASREG Maßzeichnung KW ⁄ TW - extern Dimensional drawing KW ⁄ TW - external Plan coté KW ⁄ TW - externe Габаритный чертеж KW ⁄ TW - наружный M12x1,5 M16x1,5 Sensor ø3 13 7 KW ⁄ TW - extern mit abgesetzten Fühlerkopf KW ⁄...