When Errors Occur
G When an error is occurring in a group, that group's Individual ON/OFF lamp will constantly flash. Moreover, when an error is detected by the
controller, an output function can be used to give an output signal.
Error details
Unit error
1
(air conditioner, ventilation unit)
Error on ON/OFF remote controller itself/Error when
2
starting up system
When errors of type 1 listed in the above table occur, check the error code and error source address that are displayed on the local remote controller
connected to that group.
When errors of type 2 listed in the above table occur, the error code and error source address will be displayed alternatively on the screen when the
remote controller cover is removed using a slotted screwdriver. Check the error details here. (When the error of type 1 listed in the above table occur, the
error details will also be displayed on this screen.)
Make a note of the error details and call the nearest Mitsubishi Electlic supplier or call the dealer who sold the system.
5
Modifying Room Name Details
G When you want to change the room names, use a slotted screwdriver to remove the remote controller cover and pull out the room name sheet.
[Removing the remote controller cover]
Insert the head of a slotted screwdriver into one of the open slots and remove
the cover by gently rotating the screwdriver as shown in the diagram on the right.
[Removing and inserting the room name sheet]
Pull out the room name sheet sideways to the right by using onto the hole on the
right side of the room name sheet.
If the names are written in pencil, use an eraser to remove the old names and
write new names in pencil.
After writing the new room names, insert the room name sheet by following the
above procedure in the reverse order.
[Refitting the remote controller cover]
First hook the cover to the two upper claws and then fit it to the remote controller.
NOTE • When rotating the slotted screwdriver to remove the remote controller cover, rotate it in a gentle fashion taking care not to apply much force.
If too much force is applied, it could break the claw parts.
• When refitting the remote controller cover, press it down until it snaps securely shut. If the cover is not securely shut, it may fall off.
• When using the room name sheet for the first time, you need to remove the protective sheet from the front surface of the sheet.
Individual ON/OFF lamp
Individual ON/OFF lamp of the group in which the error is occurring will constantly
flash.
The error display is cancelled when the Individual ON/OFF switch of the group in
which the error is occurring is operated.
All Individual ON/OFF lamps will constantly flash.
The error display is cancelled when the Collective ON/OFF switch is operated.
PAC-YT40ANRA
CENTRALIZED
ON/OFF
GROUP SETTING
ERROR CODE
8888
ON
ADMINI STERED
OFF
GROUP
Meeting Room 1 Meeting Room 2 Meeting Room 3 Meeting Room 4
1
2
3
4
Use this hole to
remove the room
name sheet.
3