3.0 ELECTRICAL REQUIREMENTS

3.1 Electrical Requirements
#HTK-EXT operates on 120VAC, 60hz electrical service. The current
draw of this device is 1.72A.

3.2 Electrical Installation

The point of entry for electrical wiring into the #HTK-EXT is on
the rear of the termination cap assembly. If you are mounting
the termination cap before electrical work can be completed,
verify there is enough space for access to the back side of the
termination cap to run the wiring through the grommet and into
the electrical box.
The provided on/off fan speed control switch is the only
Figure 3.1, HTK-EXT Wiring Diagram
Heat Transfer Kit - Exterior #HTK-EXT R.5
approved speed control switch for this device. If you choose to
not use the provided fan speed control switch, you may wire in
an on/off switch of your choice, but you cannot wire in any other
fan speed control. Ensure any other chosen switch meets the
electrical requirements of the system listed in Section 3.1.
#HTK-EXT fan will generate sound during operation. The effects
of the increased sound level can be minimized with careful
planning during installation of the system.
When wiring the provided on/off fan speed control, the leads
coming out the switch will intercept with the hot wire leading
from the power source to the #HTK-EXT. Inside the #HTK-EXT
electrical box there will be (1) black, (1) white, and (1) green wire
leads to attach to the wiring ran from the power source.
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
BLACK
WHITE
GROUND