Temperature Protection; Factory Reset - ARMA 4x4 4S Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Temperature Protection

If the ESC temperature exceeds 105 degrees Celsius/221 degrees Fahrenheit, the ESC will
enter temperature protection mode and the green status LED will blink. Once the ESC has
cooled down it will resume normal operation after it has been turned off and back on again.
ESC Tuning Options
The ARRMA BLX brushless ESC is setup for use straight from the factory, if you want to alter the
settings for your track or driving style please see the table and steps below:
Variable
1
Low Voltage Cut-Off Threshold
2
Punch Setting
3
Brake Strength
4
Running Mode
5
Motor Rotation
To alter ESC settings
A
1. Connect a battery. Press and
hold the set button and turn on
ESC. The RED LED will flash.
4. Using the tuning chart, press
the 'set' button until the number
of red LED flashes and short
beeps equals the required value.

Factory Reset

To reset the ESC to factory default settings, connect a battery, turn the transmitter on and then turn
the car on. Press and hold the set button for 4 seconds and release. The Red and Green lights will
flash simultaneously to show you have reset. Switch the ESC off and factory reset is complete.
Setting > 1
2
LIPO
Level 1
Level 2
25%
37.5%
Fwd/Brk/Rev
Fwd/Brk
Normal
Reverse
(CCW)
(CW)
B
2. Keep holding the set button
and you will see the GREEN
LED flash/beep (the number of
green flashes represents the
variable number).
5. To save the setting,
switch the ESC off. Restart
the process to make more
changes.
16
3
4
5
Level 3
Level 4
Level 5
50%
62.5%
75%
3. To enter the selected
variable, release the set button
on the desired number of
flashes/beeps.
WWW.ARRMA-RC.COM
6
7
87.5%
100%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arb10441

Table des Matières