LOCATION AND INSTALLATION/VENTILATION
INSTALLATION CLEARANCES 36" WITH LOW BACKGUARD
EN
18" [45.7]
MIN.
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE
NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
"G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
"E" IS ELECTRICAL SUPPLY ZONE.
"W" IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8" BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
"V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
8
©2021 Hestan Commercial Corporation
COMBUSTIBLE
VENT HOOD
V
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
9-1/2"
[24.1]
18"
G
[45.7]
19"
[48.3]
3"
ELECTRICAL
[7.6]
SUPPLY
LOCATION
5"
[12.7]
FRONT VIEW
MATERIALS
W
E
6"
[15.2]
2-1/2"
[6.4]
5"
[12.7]
RANGE MODEL
KRD365/KRDS365
KRD364GD
(CONTINUED)
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
12"
[30.5]
COUNTERTOP
FULL OVERLAY
DRAWER FACE
1
" [3.2 mm]
8
FULL OVERLAY
CABINET DOOR FACE
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
FINISHED
FLOOR
W
V
(MIN)
36" [91.4]
30" [76.2]
36" [91.4]
30" [76.2]