JET NOZZLE REPLACEMENT/CHANGING PUMP
PERFORMANCE
CONGRATULATIONS! You have purchased the most
versatile jet pump in the industry. The VersaJet pump
line was designed and manufactured with dependable
and durable materials ensuring the quality, reliability, and
performance you expect from Franklin Electric products.
Understanding that not all water supply needs are the
same, Franklin designed the patent pending VersaJet to
allow you to customize its peformance quickly and easily
to meet your job site needs.
Please review the performance information to determine
which nozzle will provide the best performance
parameters for your installation. If required, through
Franklin Electric's Patent Pending nozzle removal system,
the standard nozzle, which is factory installed, can be
changed by following the instructions below.
CUSTOMIZING PUMP PERFORMANCE
Each VersaJet pump is supplied with three easily
replaced jet nozzles. Each nozzle will be marked with
a letter designator. Depending on the motor size on the
pump, the supplied nozzles will be marked with A, B, C,
or D. Refer to Figure 6 and the pump performance data
(Appendix II) to determine which nozzle you will need.
Each Nozzle, once installed will change the performance
of the pump according to the data provided.
Motor HP
Standard*
1/2
B
3/4
C
1
B
1-1/2
B
VersaJet Professional
Motor HP
Standard*
1/2
C
3/4
B
1
B
*Factory installed, for a variety of applications.
VersaJet
Performance Type
High
High Flow
Pressure
C
D
C
C
Performance Type
High
High Flow
Pressure
D
C
C
CHANGING THE JET NOZZLE
1. Remove 3/4" NPT pipe plug.
2. With the 7/16" Allen wrench provided, remove factory
installed jet nozzle.
3. Install the desired alternate jet nozzle to change the
pump's performance. Tighten the new jet nozzle to 40 in-lbs.
4. Apply a thread sealant and replace the 3/4" NPT
pipe plug.
5. Pressure switch adjustment may be required as
nozzles are changed. See "SWITCH ADJUSTMENTS".
MOTOR
NOTICE: A motor operating under normal conditions
maintains its rated performance, assuming a clean,
dry motor with proper ventilation. A dirty motor,
or one "protected" by a burlap or plastic bag, will
overheat.
MAINTENANCE
LUBRICATION
The pump requires only water for lubrication and must
WARNING
A
priming instructions before running.
A
A
A
A
A
A
Removable Jet
never be run dry.
C A U T I O N
Running the pump dry
may cause damage to the pump and
system components.
DRAINING
W A R N I N G
Before disconnecting
pump, be sure fuse box leads are
disconnected or power is turned off.
After reassembling the pump, refer to
Drain Plug
3/4" Pipe Plug