Installation Notes
LPQ250 Series
Input Specifications
Input range
85 VAC to 264VAC
120 VDC to 370 VDC
Frequency
47 - 440 Hz
<38 A peak
Inrush current
Efficiency
75% typical at full load
Power factor
0.99 typical,
meets EN61000-3-2
Meets FCC Class B
EMI filter
CISPR 22 Class B
(includes EN55022 class B and
VDE 0878 PT3 class B)
Electromagnetic
Meets IEC801-2 level 3,
compatibility
IEC801-4 level 3
and IEC801-5 level 3
Safety ground
< 0.5mA @50/60Hz, 264VAC
leakage current
input
Environmental
Operating temperature: 0°C to 50°C ambient;
derate at 2.5% / °C from 50°C to 70°C
Storage temperature:-40°C to 85°C
Thermal regulation: ± 0.04% / °C
MTBF:
> 100,000 hours at full load and 25°C
ambient conditions
Notes (refer to table)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output
voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF
capacitor.
4. Output 4 is fully floating. It can be referenced positive or negative. It is also
fully user adjustable between 5 and 25V, factory set at 5V.
5. Minimum load required for correct operation of power supply. Do not use
without minimum load connected.
6. Continuous maximum power drawn must not exceed 250W with fan cooling.
Not to be used without cooling fan.
Mating Connectors
SK1 AC Input:
Screw terminals M3.5 spade
TB1 Main DC O/p: Screw terminals M3.5 spade
SK2 Aux DC O/p: Screw terminals M3.5 spade
SK3 Auxiliary:
Housing Molex 22-01-1082
SK4, 5, 7 Fan/Aux: Housing Molex 22-01-1022
Crimps: 22/30 AWG Molex 08-50-0032
Notes
1 Specifications subject to change without notice.
2 All dimensions are in mm and (inches).
3 Output Common capacitivily coupled to chassis earth.
4 This power supply must be earthed for safe operation via SK1-3
connector.
5 Unit supplied with cover fitted.
6 Fan cooling required. Recommended position at mains terminal end
blowing into unit. 30CFM forced air required
7 Weight 1.41 kg / 3.1 lb.
Warning: Hazardous mains voltages present within
this unit. Please see enclosed 'Astec Installation and
Operating Instructions'.
250 Watts
Quad Outputs
(or 22-01-2085)
(or 22-01-2025)
(or 08-50-0114)
捷多邦,专业PCB打样工厂,24小时加急出货
Output Specifications
250W with 30CFM forced air with cover:
Maximum
200W with 30CFM forced air, without cover.
wattage
± 5% on main
Adjustment
5 - 25V on output 4
range
±2% on output 1
Cross regulation
±3% on outputs 2, 3 & 4
20 ms at 250W load and 115 VAC nominal
Hold-up time
line
Short circuit protection on all outputs. Auto
Overload
recovery. Over current limit on each output 5
protection
to 45% above peak rated output.
5V output: 6.0 to 6.7 Vdc. Output 4: 10% to
Overvoltage
25% above output voltage setting. Recycle
protection
AC to reset.
5V / 100mA regulated; output maintained
Supervisory
output
when main outputs inhibited. (for use with
inhibit and power good function)
12V / 200mA; output maintained
Fan supply
when power supply inhibited.
output
Safety
VDE
0805/EN60950 (IEC950)
UL
UL1950
CSA
CSA 22-2-234 Level 3
NEMKO
EN 60950/EMKO-TUE (74-sec) 203
BABT
EN60950/BS7002
CB
Certificate and report
This product is CE marked following
the provisions of the Low Voltage
Directive 73/23/EEC
Auxiliary Connections
1 Remote sense - optional connection- can
compensate for up to 0.5V drop; internal
local sense connected if not used. Protected
against reverse connection.
2 AC Power Fail signal;-TTL compatible signal
goes high 50-150ms after switch on. Goes
low >4 ms before 5V drops to 4.75V.
3 DC Power OK:- TTL compatible signal goes
high at same time as AC Power Fail. Goes
low when 5V drops to 4.75V.
4 Remote Inhibit. Connecting pin 3 to pin 5
(common) will inhibit the outputs.
5 Remote Enable. To convert to enable, cut
jumper J1; connecting pin 4 to pin 5 will
enable outputs.
6 Paralleling power supplies - when the 'C
share' signal is connected between two
power supplies the main 5V outputs will
current share.
Fusing
Input fuse 6.3A 20mm Quick Acting HBC
mains fuse - only replace with same type
and rating to maintain safety standards.

Publicité

loading

Sommaire des Matières pour ASTEC LPQ250 Série

  • Page 1 Fusing Warning: Hazardous mains voltages present within Input fuse 6.3A 20mm Quick Acting HBC this unit. Please see enclosed ‘Astec Installation and mains fuse - only replace with same type Operating Instructions’. and rating to maintain safety standards.
  • Page 2: Pin Assignments

    +5V supervisory supply Common Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.
  • Page 3: Caractéristiques D'entrée

    Fusible Attention: Tension secteur dangereuse sur cette Fusible d’entrée 6.3A 20mm rapide HBC à alimentation. Veuillez consulter la notice d’installation remplacer par le même type et la même valeur ASTEC et les instructions d’utilisation. pour maintenir les homologations de sécurité.
  • Page 4: Plan Mecanique

    +5V supervisory supply Commun Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.
  • Page 5 Bedienungs Anleitung LPQ250 Serie 250 Watt Vierfach Ausgang Eingangs Spezifikationen Ausgangs Spezifikationen 85 VAC to 264 VAC Maximale 250W mit Gehäuse und 51m /Std Eingangsbereich Ausgangsleistung 120 VDC bis 370 VDC (30CFM) Luftkühlung 47 - 440 Hz 200W ohne Gehäuse und 51m /Std Frequenz (30CFM) Luftkühlung...
  • Page 6 +5V supervisory supply Common Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.

Ce manuel est également adapté pour:

Lpq252-cLpq253-c