T 4780 / MD4780
₋ The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable anesthetic mixture
with air of with oxygen or nitrous oxide.
₋ Warning: No servicing/maintenance while the ME equipment is in use.
₋ To avoid measurement errors, please avoid the condition of strong electromagnetic field radiated interference signal or
electrical fast transient/burst signal.
₋ The blood pressure monitor and the cuff are suitable for use within the patient environment. If you are allergic to
polyester, nylon or plastic, please don't use this device.
₋ If you experience discomfort during a measurement, such as pain in the wrist or other complaints, press the START/STOP
button to release the air immediately from the cuff. Loosen the cuff and remove it from your wrist.
₋ If the cuff pressure reaches 40 kPa (300 mmHg), the unit will automatically deflate. Should the cuff not deflate when
pressures reaches 40 kPa (300 mmHg), detach the cuff from the wrist and press the START/STOP button to stop inflation.
₋ Before use, make sure the device functions safely and is in proper working condition. Check the device, do not use the
device if it is damaged in any way. The continuous use of a damaged unit may cause injury, improper results, or serious
danger.
₋ Do not wash the cuff in a washing machine or dishwasher!
₋ The service life of the cuff may vary by the frequency of washing, skin condition, and storage state. The typical service
life is 10000 times.
₋ The operator shall not touch output of batteries and the patient simultaneously.
₋ Cleaning :Dust environment may affect the performance of the unit. Please use the soft cloth to clean the whole unit
before and after use. Don't use any abrasive or volatile cleaners.
₋ Keep the unit out of reach of infants, young children or pets to avoid inhalation or swallowing of small parts. It is
dangerous or even fatal.
₋ Be careful to strangulation due to cables and hoses, particularly due to excessive length.
₋ At least 30 min required for ME equipment to warm from the minimum storage temperature between uses until it is
ready for intended use. At least 30 min required for ME equipment to cool from the maximum storage temperature
between uses until it is ready for intended use.
₋ Wireless communications equipment such as wireless home network devices, mobile phones, cordless telephones and
their base stations, walkie-talkies can affect this equipment and should be kept at least a distance d away from the
equipment. The distance d is caculated by the MANUFACTURER from the 80 MHz to 5.8 GHz column of Table 4 and Table
9 of IEC 60601-1-2:2014, as appropriate.
₋ There is no luer lock connectors are used in the construction of tubing, there is a possibility that they might be
inadvertently connected to intravascular fluid systems, allowing air to be pumped into a blood vessel.
₋ Please use the device under the environment which was provided in the user manual. Otherwise, the performance and
lifetime of the device will be impacted and reduced.