Economy mode, the heater will operate ONLY
during the filtration cycles. The pump will cir-
culate for approximately two minutes several
times throughout the day to sample water
temperature.
Sleep mode, the spa will heat to within 20°F
(10°C) of the set temperature only during filter
cycles.
The selected mode will be displayed in the
LED window of the control panel. When in
Standard mode, the letters ST are displayed,
followed by the water temperature. When in
Economy mode, the letters EC are displayed
alternately with the water temperature. When
in Sleep mode, the letters SL are displayed
alternately with the water temperature.
Setting the Time and Filtration Cycles
Preset Filter Cycles
The spa control system is designed with two
filter cycles. The first filter cycle turns on 6
minutes after power is supplied to the spa. The
second filter cycle turns on 12 hours later. Fil-
ter cycles are pre-set for a two hour duration.
NOTE: To properly clean and maintain spa,
a total filter time of at least four hours per
day is recommended.
Changing Filter Cycle Start Time
The start/stop times of the filter cycle begin
6 minutes after the spa set time is established.
Set time is based on the time of day that the
spa is powered up. Set time may only be
changed by disconnecting power from the
spa and re-connecting it at the desired start
time. For example, if you want the filter cycle
to begin at 9:00 PM, unplug the spa and
re-connect it at 8:54 PM (remember the
6 minute wait period). The cycle will begin at
9:00 PM and will repeat beginning at 9:00 AM.
18
Each cycle will run for the prescribed number
of hours.
Changing Filter Cycle Duration
The duration of a filter cycle can be set in
hour increments of 2, 4, 6, 8, or continuous.
For example, a 2 hour cycle will complete once
every 12 hours for a total of 4 hours per day.
The amount of time needed to filter you spa
will depend on usage and ambient conditions.
You will need to program you filter cycles
based upon your personal use.
To change the duration of the filter cycles
touch the TEMP or Warm (if so equipped) pad
and then touch the
JETS or JETS 1 pad.
Touch the TEMP/WARM pad to adjust the
cycle duration to the desired setting. After
each press, the duration of the cycle will be
displayed in the LED window as follows:
F2 2 Hours for each cycle, 4 hours per day
F4 4 Hours for each cycle, 8 hours per day
F6 6 Hours for each cycle, 12 hours per day
F8 8 hours for each cycle, 16 hours per day
FC Continuous filtration, 24 hours per day
To exit the filter-set procedure, touch JETS 1.
The LED window will display the current water
temperature.
If a change is made to the duration while the
spa is in a filtration cycle, it will take effect
immediately. If the change is made outside a
filtration cycle, it will take effect at the start
of the next scheduled cycle.
NOTE: When power to the spa is denied
(disconnect, power outage), the controls
may revert to the default factory settings.
Any adjustments to set temperature or
filter cycle duration may need to be
reprogrammed.
CALIFORNIA COOPERAGE