Software Parameters - DART Controls DM8000 Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Software Parameters

Parameter
0
Selecting this item exits to Running Mode
Read-Only Parameters
1
Model Number
2
Software Build
3
Hardware Version
4
Serial Number – Major (reserved)
5
Serial Number – Minor (reserved)
General Setup
10
Operating Mode
11
Display Intensity
14
Input Trigger / Prescaler Setup
16
Counter Mode Reset Configuration
Signal Input #1 (S1) Setup
20
Display Reference
21
Reference RPM
22
Pulses Per Revolution
23
Recovery Rate
24
Display Smoothing / Averaging
25
Decimal Point Position
26
Auto-Ranging Configuration
27
Counter Mode Reset / Preload Value
30
Reserved
31
Reserved
32
Reserved
33
Reserved
34
Reserved
35
Reserved
36
Reserved
37
Counter Gate Configuration
Description
9
Value Range
(units)
n/a
n/a
1 – 9999
1 – 9999
n/a
n/a
1 – Rate Mode
2 – Time Mode
3 – Up Counter
4 – Down Counter
5 – Up / Down Counter
0 – 31 (Dim – Bright)
1 - Every Rising Edge
2 – Every Falling Edge
3 – Falling Edge / 4
4 – Falling Edge / 16
1 – Reset Disabled
2 – Reset on Keypress
3 – Reset on S2 Low
4 – Reset on S2 High
1 – 9999 (Display Units)
1 – 9999 (RPM)
1 – 9999 (PPR)
0 – 1000 (1/2 seconds)
0 – Disabled
> 0 – Recovery 1/2 seconds
0 – 60 (seconds)
0 – Disabled
> 0 – Averaging Seconds
0 – DP Disabled (XXXX)
1 – X.XXX
2 – XX.XX
3 – XXX.X
4 – XXXX.
0 – Auto-Ranging Off
1 – Auto-Range on Overflow
2 – Auto-Ranging On
0 – 9999 (counts)
1 – Disabled
2 – Counting Enabled (Low)
3 – Counting Enabled (High)
Factory
User
Default
Settings
n/a
80
n/a
n/a
n/a
n/a
1
20
1
1
1000
1000
1
10
1
0
0
0
1

Publicité