3

Error notifications

3.1 Error notifications in the display 3:
An error notification indicates an electrical defect of
the system.
The control unit is no longer ready for operation:
1. Note error notification.
2. Switch off main fuses of the control unit in the fuse
box.
3. Inform your customer service department.
4. Identify the control unit as defective.
You can give your customer service department in-
formation on possible errors with the following error
notifications in the display 3.
The error notifications mean:
E-F1:
Cable short-circuit / disrupted
connection / heater sensor defective.
E-F2:
Cable short-circuit / disrupted
connection / bench sensor defective.
E- 12:
Disrupted connection or damage to the
excess temperature fuse.
E-P I:
Damage to the potentiometer 4 for the
temperature setting.
E-P 2:
Damage to the potentiometer 6 of the
evaporator setting.
3.2
Red control light 2 flashes:
The control unit automatically switches the heating off
when the excess temperature fuse responds.
The control unit is no longer ready for operation:
1. Switch off the main fuses of the control device in
the fuse box.
2. Inform your customer service department.
3. Identify the control device as defective.
Instructions for use - Figure 5
• 21 •
4
Switching control unit and inte-
rior lighting on/off
4.1 Switching on control device
WARNING – Fire hazard:
Before switching on the sauna control unit
and when setting a preset time (time until
the heater starts) it must be ensured that
no combustible objects are placed on the
heater.
1. Switch on control unit using ON/OFF switch 8 .A
self-test is conducted:
• The control lights 1 / 2 illuminate briefly.
• A buzzer sounds once.
• 00.00 flashes in the display 3
• The control unit is ready operation.
4.2 Switching off control unit
1. Switch off the ON/OFF switch 8 when the sauna/
evaporator bath has finished.
• The control lights 1 / 2 are extinguished.
• The control unit is switched off.
4.3 Switching the internal lighting on/off
1. Button 7 switches the internal sauna lightening
ON/OFF.