- COMPLETE LEARNING:
Check if the leaves are closed, and then press the F push-button for
more than 3 seconds: DL10 LED begins flashing and leaf 1 begins the
opening movement. The following functions can be commanded by
the OPEN A pulses (by radio control or key push-button):
1° OPEN - Leaf 1 Decelerates at opening (it stops automatically
on reaching the stop limit)
2° OPEN - Leaf 2 opening movement begins
3° OPEN - Leaf 2 Decelerates at opening (it stops automatically
on reaching the stop limit)
4° OPEN - Leaf 2 closing movement begins
5° OPEN - Leaf 2 decelerates at closing (it stops automatically on
reaching the stop limit)
6° OPEN - Leaf 1 closing movement begins
7° OPEN - Leaf 1 Decelerates at closing (it stops automatically on
reaching the stop limit)
The DL10 LED stops flashing and the gate is ready for normal operation.
Notes:
•The deceleration pulse should be supplied a little earlier with
respect to the stop limit to prevent the leaf reaching it at full
speed (it would be taken for an obstacle).
•If only one leaf is present, the entire sequence must
nevertheless be effected. When the leaf has finished opening,
supply 5 Open pulses until the leaf begins to close, and then
resume normal operation.
•For a correct operation, the mechanical limit stop during
opening and closing is absolutely necessary.
6.3.4. LEARNING TIMES WITH ENCODER + LIMIT-SWITCHES
Learning with the encoder + Limit-switches can be done in two different
ways:
- SIMPLE LEARNING:
Carry out the same procedure as for limit-switch learning. The encoder
is used only as an obstacle sensor.
- COMPLETE LEARNING:
Carry out the same procedure as for limit-switch learning. The encoder
is used only as an obstacle sensor.
Note:
•If some limit-switches are not installed, start the corresponding
deceleration by supplying an Open pulse (which replaces
the limit-switch).
•If only one leaf is present, the entire sequence must
nevertheless be effected. When the leaf has finished opening,
supply 5 Open pulses until the leaf begins to close, and then
resume normal operation.
6.4.
PRE-FLASHING
If you wish to increase the equipment's safety level, you can activate
the pre-flashing function which enables the flashing lamp to go on 5
seconds before the leaf starts to move.
Pre-flashing activation procedure:
1 - check if the gate is closed
2 - open and keep open the Stop contact
3 - check if the DL10 LED is OFF (if lighted, pre-flashing is already
active)
4 - briefly press the F push-button and check if the DL10 LED lights
up.
5 - close the Stop contact (DL10 goes OFF).
Procedure for disabling the function:
1 - check if the gate is closed
2 - open and keep open the Stop contact
3 - check if the DL10 LED is lighted (if OFF, pre-flashing is already
disabled)
4 - briefly press the F push-button and check if the DL10 LED is OFF.
5 - close the Stop contact
7. AUTOMATED SYSTEM TEST
When you have finished programming, check if the system is operating
correctly.
Most important of all, check if the force is adequately adjusted and if
the safety devices are operating correctly.