4.4
LED cycle setting
LED (2) indicates that recording is active. The LED signal can be set to appear
every 5, 10, 15, 20, 25 or 30 seconds.
4.5
Einstellungen Alarmfunktion
Activate high and low alarm
Temperature
High alarm
Low alarm
Humidity
High alarm
Low alarm
4.6
Unit of temperature
Measured values can be shown in °C or °F.
5
Setup menu - real time measurement
Measurement-specific settings on the connected device can be defined
in the Setup menu.
!
New configuration automatically deletes all existing data.
Settings
Unit of
temperature
Unit of
moisture
The alarm range can be freely defined for the two
measured variables temperature and relative humidity.
If the measuredvalue goes above or below the set cap
or floor, the alarm LED (3) flashes every 10 seconds.
Temperature below set value: LED (3) flashes yellow
Temperature above set value: LED (3) double-flashes
yellow
Humidity below set value: LED (3) flashes red
Humidity above set value: LED (3) double-flashes red
Real time
Sampling rate
Max.
Device name
Reset
Reset to factory
settings
ClimaData Stick
Configure
Cancel
Save
Close Setup menu
settings
without saving
Maximum number
of measurements
EN
15